Suppr超能文献

体外心脏起搏:电极放置对起搏阈值的影响

External cardiac pacing: influence of electrode placement on pacing threshold.

作者信息

Falk R H, Ngai S T

出版信息

Crit Care Med. 1986 Nov;14(11):931-2.

PMID:3769503
Abstract

External cardiac pacing is a recently reintroduced, effective method for emergency cardiac stimulation. The optimal electrode position and polarity for external pacing were determined in two groups of normal subjects. In six subjects there was no significant difference in pacing threshold when electrodes were positioned as follows: negative electrode in left parasternal region, positive electrode in right subscapular region; negative electrode in left parasternal region, positive electrode in left subscapular region; or negative electrode at cardiac apex, positive electrode in right parasternal region. In the remaining ten patients, pacing attempts were ineffective when electrode polarity was reversed. We conclude that exact electrode positioning is not crucial for external cardiac pacing, as long as the anterior or apical electrode is negative.

摘要

体外心脏起搏是一种最近重新引入的、用于紧急心脏刺激的有效方法。在两组正常受试者中确定了体外起搏的最佳电极位置和极性。在六名受试者中,当电极按以下方式放置时,起搏阈值没有显著差异:负极位于左胸骨旁区域,正极位于右肩胛下区域;负极位于左胸骨旁区域,正极位于左肩胛下区域;或负极位于心尖,正极位于右胸骨旁区域。在其余十名患者中,当电极极性反转时,起搏尝试无效。我们得出结论,只要前电极或心尖电极是负极,精确的电极定位对于体外心脏起搏并不关键。

相似文献

7
Use of a retained guidewire to improve the left ventricular pacing threshold.
Pacing Clin Electrophysiol. 2007 Oct;30(10):1285-7. doi: 10.1111/j.1540-8159.2007.00854.x.