Abstract

Electrogastrography (EGG) non-invasively evaluates gastric motility but is viewed as lacking clinical utility. Gastric Alimetry is a new diagnostic test that combines high-resolution body surface gastric mapping (BSGM) with validated symptom profiling, with the goal of overcoming EGG's limitations. This study directly compared EGG and BSGM to define performance differences in spectral analysis. Comparisons between Gastric Alimetry BSGM and EGG were conducted by protocolized retrospective evaluation of 178 subjects [110 controls; 68 nausea and vomiting (NVS) and/or type 1 diabetes (T1D)]. Comparisons followed standard methodologies for each test (pre-processing, post-processing, analysis), with statistical evaluations for group-level differences, symptom correlations, and patient-level classifications. BSGM showed substantially tighter frequency ranges vs EGG in controls. Both tests detected rhythm instability in NVS, but EGG showed opposite frequency effects in T1D. BSGM showed an 8× increase in the number of significant correlations with symptoms. BSGM accuracy for patient-level classification was 0.78 for patients vs controls and 0.96 as compared to blinded consensus panel; EGG accuracy was 0.54 and 0.43. EGG detected group-level differences in patients, but lacked symptom correlations and showed poor accuracy for patient-level classification, explaining EGG's limited clinical utility. BSGM demonstrated substantial performance improvements across all domains.

摘要

胃电图(EGG)非侵入性地评估胃动力,但被认为缺乏临床实用性。胃测压是一种新的诊断测试,它将高分辨率体表胃映射(BSGM)与经过验证的症状分析相结合,旨在克服 EGG 的局限性。本研究通过对 178 名受试者(110 名对照;68 名恶心和呕吐(NVS)和/或 1 型糖尿病(T1D))的协议化回顾性评估,直接比较了 EGG 和 BSGM 在频谱分析中的性能差异。胃测压 BSGM 和 EGG 之间的比较是通过对每个测试(预处理、后处理、分析)进行标准方法进行的,对组间差异、症状相关性和患者水平分类进行了统计学评估。BSGM 在对照组中显示出与 EGG 相比频率范围更紧密。两种测试都在 NVS 中检测到节律不稳定,但 EGG 在 T1D 中显示出相反的频率效应。BSGM 与症状的显著相关性数量增加了 8 倍。BSGM 对患者水平分类的准确性为 0.78 (患者与对照)和 0.96 (与盲法共识小组相比);EGG 的准确性为 0.54 和 0.43。EGG 在患者中检测到组间差异,但缺乏症状相关性,对患者水平分类的准确性差,这解释了 EGG 有限的临床实用性。BSGM 在所有领域都显示出显著的性能改进。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/a677/10495352/a8f4ea4d4712/41598_2023_41645_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验