Martínez-Plaza Elena, López-de la Rosa Alberto, Ossa-Calderon Carolina, Blázquez-Arauzo Francisco, López-Miguel Alberto, Maldonado Miguel J
Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Paseo de Belén 17, 47011, Valladolid, Spain.
Red Temática de Investigación Colaborativa en Oftalmología (OftaRed), Instituto de Salud Carlos III, Madrid, Spain.
Int Ophthalmol. 2023 Dec;43(12):4711-4718. doi: 10.1007/s10792-023-02871-3. Epub 2023 Sep 11.
To evaluate the effect of EVO+ Visian Implantable Collamer Lens (ICL) implantation on the iridocorneal angle pigmentation and structures.
Myopic refractive surgery candidates who underwent posterior chamber EVO+ ICL implantation were evaluated preoperatively and 3 and 6 months postoperatively. High-resolution images of the iridocorneal angle (nasal, superior, temporal and inferior quadrants) were acquired during gonioscopy. A masked observer, blinded to study visits and patients' information, evaluated the angle width, apparent iris root insertion, iris configuration, and trabecular meshwork pigmentation according to the Spaeth scale in two different occasions. The intra-rater reliability was estimated using the weighted Gwet's Agreement Coefficient (AC2). Differences between visits were analyzed using the Cochran Q test or the Friedman test.
Twenty-one patients (13 females and 8 males) aging 31.3 ± 6.3 years old were recruited. The intra-rater reliability of gonioscopy assessment was excellent for every parameter assessed (AC2 ≥ 0.97). No significant differences were found among the study visits for any quadrant in the angle width (p ≥ 0.74), apparent iris root insertion (p ≥ 0.22), iris configuration (p ≥ 0.21) and trabecular meshwork pigmentation (p ≥ 0.24). Mean pigmentation of trabecular meshwork for the four quadrants did not vary either among visits (p = 0.25).
The EVO+ ICL implantation after uneventful procedures appears not to clinically affect the iridocorneal angle pigmentation and/or structures during a short-medium follow-up using gonioscopy assessment. The intra-rater reliability of glaucoma specialists assessing iridocorneal angle structures using gonioscopy images is very high.
评估EVO+ Visian可植入式接触镜(ICL)植入术对虹膜角膜角色素沉着和结构的影响。
对接受后房EVO+ ICL植入术的近视屈光手术候选者在术前、术后3个月和6个月进行评估。在房角镜检查期间获取虹膜角膜角(鼻侧、上方、颞侧和下方象限)的高分辨率图像。一名对研究访视和患者信息不知情的蒙面观察者在两种不同情况下根据Spaeth量表评估房角宽度、虹膜根部插入情况、虹膜形态和小梁网色素沉着。使用加权Gwet一致性系数(AC2)估计评估者内部的可靠性。使用 Cochr an Q检验或Friedman检验分析访视之间的差异。
招募了21名年龄为31.3±6.3岁的患者(13名女性和8名男性)。房角镜评估的评估者内部可靠性对于所评估的每个参数都非常好(AC2≥0.97)。在房角宽度(p≥0.74)、虹膜根部插入情况(p≥0.22)、虹膜形态(p≥0.21)和小梁网色素沉着(p≥0.24)的任何象限中,研究访视之间均未发现显著差异。四个象限的小梁网平均色素沉着在访视之间也没有变化(p = 0.25)。
在短期至中期随访中,使用房角镜评估,EVO+ ICL植入术后若手术过程顺利,似乎不会对虹膜角膜角色素沉着和/或结构产生临床影响。青光眼专家使用房角镜图像评估虹膜角膜角结构的评估者内部可靠性非常高。