From Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Valladolid, Spain; Red Temática de Investigación Colaborativa en Oftalmología (OftaRed), Instituto de Salud Carlos III, Madrid, Spain.
From Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Valladolid, Spain; Red Temática de Investigación Colaborativa en Oftalmología (OftaRed), Instituto de Salud Carlos III, Madrid, Spain.
Am J Ophthalmol. 2021 Jun;226:117-125. doi: 10.1016/j.ajo.2021.02.005. Epub 2021 Feb 9.
To assess the effect of EVO+ (V5) Visian implantable collamer lens implantation on mesopic visual performance, quality of vision (QoV), and quality of life (QoL).
Prospective interventional case series.
Thirty-six eyes of 36 participants who underwent EVO+ implantation for myopia were evaluated preoperatively and at postoperative visits at 1 week and 1, 3, and 6 months. Visual acuity (VA) and mesopic contrast sensitivity (CS) with and without halogen- and xenon-type glare sources were evaluated at each visit. Subjective QoV was assessed with the QoV questionnaire and QoL assessed with the Quality of Life Impact of Refractive Correction (QIRC) questionnaire at each visit. Ring-shaped dysphotopsia was also assessed at each postoperative visit. Linear, cumulative link and logit mixed models were fitted to analyze the effect of the EVO+.
Following EVO+ implantation, VA significantly (P ≤ .012) improved at the 4 postoperative visits. Mesopic CS progressively improved at 1, 3, and 6 months postoperatively (P ≤ .012). Halogen glare CS decreased at 1 week and halogen and xenon glare CS improved at 6 months (P ≤ .016). Photostress recovery time after halogen glare improved at 3 and 6 months (P ≤ .004). QoV scores improved at 1 week and 3 and 6 months (P ≤ .001). QIRC scores improved postoperatively (P < .001). Ring-shaped dysphotopsia decreased at 3 and 6 months (P ≤ .007).
EVO+ implantation provides good mesopic visual performance, QoV, and QoL during up to 6 months follow-up. Some activities performed under mesopic conditions with glare sources may be affected during the first postoperative week. Ring-shaped dysphotopsia is negligibly bothersome 6 months after surgery.
评估 EVO+(V5)可植入性虹膜夹型人工晶状体植入术对中间视觉性能、视觉质量(QoV)和生活质量(QoL)的影响。
前瞻性干预性病例系列研究。
对 36 例(36 只眼)接受 EVO+植入术矫正近视的患者进行术前评估,并在术后 1 周、1 个月、3 个月和 6 个月时进行随访。每次随访时评估视力(VA)和中间视觉对比敏感度(CS),并评估有无卤钨和氙灯光源眩光。每次随访时用 QoV 问卷评估主观 QoV,用屈光矫正生活质量影响问卷(QIRC)评估生活质量。每次术后随访时还评估环形晕影。采用线性、累积链接和对数混合模型分析 EVO+的影响。
EVO+植入术后,VA 在 4 次术后随访时均显著提高(P≤.012)。中间视觉 CS 在术后 1、3 和 6 个月时逐渐提高(P≤.012)。1 周时卤钨光 CS 下降,6 个月时卤钨和氙光 CS 改善(P≤.016)。卤钨光眩光后光应激恢复时间在 3 个月和 6 个月时改善(P≤.004)。QoV 评分在 1 周和 3 个月及 6 个月时提高(P≤.001)。QIRC 评分术后提高(P<.001)。环形晕影在 3 个月和 6 个月时减少(P≤.007)。
EVO+植入术在长达 6 个月的随访中提供了良好的中间视觉性能、QoV 和 QoL。术后第 1 周,一些在有眩光源的中间视觉条件下进行的活动可能会受到影响。术后 6 个月时,环形晕影的困扰可忽略不计。