Suppr超能文献

腕戴加速度计在自由生活评估期间的佩戴依从性是否会减弱?一项 NHANES 分析。

Does Wrist-Worn Accelerometer Wear Compliance Wane over a Free-Living Assessment Period? An NHANES Analysis.

机构信息

Energy Metabolism Section, National Institute of Diabetes, Digestive and Kidney Diseases, Diabetes, Endocrinology, and Obesity Branch, National Institutes of Health (NIH), Bethesda, MD.

Metabolic Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Rockville, MD.

出版信息

Med Sci Sports Exerc. 2024 Feb 1;56(2):209-220. doi: 10.1249/MSS.0000000000003301. Epub 2023 Sep 12.

Abstract

PURPOSE

Accelerometers are used to objectively measure physical behaviors in free-living environments, typically for seven consecutive days or more. We examined whether participants experience "wear fatigue," a decline in wear time day over day, during typical assessment period acquired in a nationally representative sample of 6- to 80-yr-olds in the United States.

METHODS

Participants were instructed to wear an ActiGraph GT3X+ on their nondominant wrist continuously for seven consecutive days. Participants with seven complete days of recorded data, regardless of wear status, were included in the analyses ( N = 13,649). Wear was scored with the sleep, wake, and nonwear algorithm.

RESULTS

Participants averaged 1248 ± 3.6 min·d -1 (mean ± SE) of wear over the assessment, but wear time linearly decreased from day 1 (1295 ± 3.2 min) to day 7 (1170 ± 5.3 min), resulting in a wear fatigue of -18.1 ± 0.7 min·d -1 ( β ± SE). Wear fatigue did not differ by sex but varied by age-group-highest in adolescents (-26.8 ± 2.4 min·d -1 ) and lowest in older adults (-9.3 ± 0.9 min·d -1 ). Wear was lower in evening (1800-2359 h) and early morning (0000-0559 h) compared with the middle of the day and on weekend days compared with weekdays. We verified similar wear fatigue (-23.5 ± 0.7 min·d -1 ) in a separate sample ( N = 14,631) with hip-worn devices and different wear scoring. Applying minimum wear criteria of ≥10 h·d -1 for ≥4 d reduced wear fatigue to -5.3 and -18.7 min·d -1 for the wrist and hip, respectively.

CONCLUSIONS

Patterns of wear suggest noncompliance may disproportionately affect estimates of sleep and sedentary behavior, particularly for adolescents. Further study is needed to determine the effect of wear fatigue on longer assessments.

摘要

目的

加速度计用于客观测量自由活动环境中的身体行为,通常连续测量 7 天或更长时间。我们研究了在一项美国具有代表性的 6 至 80 岁人群样本中,参与者是否会在典型评估期间经历“佩戴疲劳”,即佩戴时间逐日减少。

方法

参与者被指示连续 7 天在非优势手腕上佩戴 ActiGraph GT3X+。无论佩戴状态如何,只要有 7 天完整记录数据的参与者均纳入分析(N=13649)。佩戴情况通过睡眠、清醒和非佩戴算法进行评分。

结果

参与者在评估期间的平均佩戴时间为 1248±3.6 min·d-1(平均值±SE),但佩戴时间从第 1 天(1295±3.2 min)线性减少到第 7 天(1170±5.3 min),导致佩戴疲劳为-18.1±0.7 min·d-1(β±SE)。佩戴疲劳与性别无关,但因年龄组而异-青少年最高(-26.8±2.4 min·d-1),老年人最低(-9.3±0.9 min·d-1)。与白天和工作日相比,傍晚(1800-2359 小时)和清晨(0000-0559 小时)的佩戴时间较低,周末也较低。我们在另一个样本(N=14631)中验证了类似的佩戴疲劳(-23.5±0.7 min·d-1),该样本使用髋部佩戴设备和不同的佩戴评分。应用最小佩戴标准≥10 h·d-1至少 4 d 将腕部和髋部的佩戴疲劳分别降低至-5.3 和-18.7 min·d-1。

结论

佩戴模式表明不遵守规定可能会不成比例地影响睡眠和久坐行为的估计,尤其是对于青少年。需要进一步研究以确定佩戴疲劳对更长时间评估的影响。

相似文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验