To validate measurement of predicted earmold wideband real-ear-to-coupler difference (wRECD) using an integrated pressure level (IPL) calibrated transducer and the incorporation of an acoustically measured tubing length correction.
Unilateral earmold SPL wRECD using varied hearing aid tubing length and the proposed predicted earmold IPL wRECD measurement procedure were completed on all participants and compared.
22 normal hearing adults with normal middle ear status were recruited.
There were no clinically significant differences between probe-microphone and predicted earmold IPL wRECD measurements between 500 and 2500 Hz. Above 5000 Hz, the predicted earmold IPL wRECD exceeded earmold SPL wRECDs due to lack of standing wave interference. Test-retest reliability of IPL wRECD measurement exceeded the reliability of earmold SPL wRECD measurement across all assessed frequencies, with the greatest improvements in the high frequencies. The acoustically measured tubing length correction largely accounted for acoustic effects of the participant's earmold.
IPL-based measurements provide a promising alternative to probe-microphone earmold wRECD procedures. Predicted earmold IPL wRECD is measured without probe-microphone placement, agrees well with earmold SPL wRECDs and is expected to extend the valid bandwidth of wRECD measurement.
验证使用集成压力级(IPL)校准换能器和纳入声学测量管长校正的预测耳模宽带真耳耦合差(wRECD)的测量。
在所有参与者中完成单侧耳模 SPL wRECD 使用不同的助听器管长和提出的预测耳模 IPL wRECD 测量程序,并进行比较。
招募了 22 名具有正常中耳状态的正常听力成年人。
在 500Hz 至 2500Hz 之间,探头麦克风和预测耳模 IPL wRECD 测量之间没有临床显著差异。在 5000Hz 以上,由于缺少驻波干扰,预测耳模 IPL wRECD 超过了耳模 SPL wRECD。在所有评估频率上,IPL wRECD 测量的测试-重测可靠性均超过了耳模 SPL wRECD 测量的可靠性,高频的改善最大。声学测量的管长校正在很大程度上解释了参与者耳模的声学效应。
基于 IPL 的测量为探头麦克风耳模 wRECD 程序提供了一种有前途的替代方法。无需探头麦克风放置即可测量预测耳模 IPL wRECD,与耳模 SPL wRECD 吻合良好,有望扩展 wRECD 测量的有效带宽。