Department of Cardiovascular Surgery, St. Luke's International Hospital, Tokyo, Japan.
Department of Cardiovascular Surgery, National Hospital Organization, Osaka National Hospital, Osaka, Osaka, Japan.
Ann Thorac Cardiovasc Surg. 2024 Jan 26;30(1). doi: 10.5761/atcs.oa.23-00089. Epub 2023 Sep 29.
Coronary anastomosis is the most key factor to accomplish coronary artery bypass grafting, which is one of the largest areas in cardiovascular surgery. Although we have organized on-site simulator training courses of coronary anastomosis using BEAT YOUCAN, it became difficult to continue it because of COVID-19. Therefore, we established a real-time evaluation sheet instead of an Objective Structured Assessment of Technical Skills (OSATS) evaluation sheet. The purposes of this study was to develop the real-time assessment system and to prove the correlation between the score obtained by the OSATS and the score obtained by the real-time evaluation system.
A total of 22 videos from the qualifying round of real-time coronary anastomosis competition evaluated by both the modified OSATS and the real-time evaluation system were utilized in this study. The global rating score of OSATS was compared with the global rating score of real-time evaluation system.
When examined the relationship between the OSATS total score and the real-time total score, there was a significant correlation (R = 0.752, p <0.001). The OSATS general definition score and the real-time total score also showed a strong correlation (R = 0.733, p <0.001).
We developed a real-time assessment sheet to evaluate coronary anastomosis. This assessment sheet had a good correlation with the OSATS evaluation sheet.
冠状动脉吻合是完成冠状动脉旁路移植术的最关键因素,它是心血管外科学中最大的领域之一。尽管我们已经组织了使用 BEAT YOUCAN 的冠状动脉吻合现场模拟培训课程,但由于 COVID-19 的原因,继续进行这项培训变得困难。因此,我们建立了实时评估表,而不是客观结构化评估技术技能(OSATS)评估表。本研究的目的是开发实时评估系统,并证明 OSATS 评分与实时评估系统评分之间的相关性。
本研究共使用了 22 个来自实时冠状动脉吻合术竞赛资格赛的视频,这些视频由改良的 OSATS 和实时评估系统进行了评估。比较了 OSATS 的全球评分与实时评估系统的全球评分。
当检查 OSATS 总分和实时总分之间的关系时,发现存在显著相关性(R = 0.752,p <0.001)。OSATS 一般定义评分与实时总分也显示出很强的相关性(R = 0.733,p <0.001)。
我们开发了一种用于评估冠状动脉吻合术的实时评估表。该评估表与 OSATS 评估表具有良好的相关性。