Suppr超能文献

电静息磁场

Electrically silent magnetic fields.

作者信息

Roth B J, Wikswo J P

出版信息

Biophys J. 1986 Oct;50(4):739-45. doi: 10.1016/S0006-3495(86)83513-5.

Abstract

There has been a significant controversy over the past decade regarding the relative information content of bioelectric and biomagnetic signals. In this paper we present a new, theoretical example of an electrically-silent magnetic field, based on a bidomain model of a cylindrical strand of tissue generalized to include off-diagonal components in the conductivity tensors. The physical interpretation of the off-diagonal components is explained, and analytic expressions for the electrical potential and the magnetic field are found. These expressions show that information not obtainable from electrical potential measurements can be obtained from measurements of the magnetic field in systems with conductivity tensors more complicated than those previously examined.

摘要

在过去十年中,关于生物电信号和生物磁信号的相对信息含量一直存在重大争议。在本文中,我们基于一个圆柱形组织束的双域模型(该模型已推广到包括电导率张量中的非对角分量),给出了一个电沉默磁场的新的理论示例。解释了非对角分量的物理解释,并找到了电势和磁场的解析表达式。这些表达式表明,在电导率张量比先前研究的更复杂的系统中,从电势测量中无法获得的信息可以从磁场测量中获得。

相似文献

1
Electrically silent magnetic fields.电静息磁场
Biophys J. 1986 Oct;50(4):739-45. doi: 10.1016/S0006-3495(86)83513-5.
3

引用本文的文献

3
The magnetocardiogram.心磁图
Biophys Rev (Melville). 2024 May 29;5(2):021305. doi: 10.1063/5.0201950. eCollection 2024 Jun.
5
Clinical magnetocardiography: the unshielded bet-past, present, and future.临床磁心动图:无屏蔽的过去、现在与未来。
Front Cardiovasc Med. 2023 Aug 10;10:1232882. doi: 10.3389/fcvm.2023.1232882. eCollection 2023.
6
A movable unshielded magnetocardiography system.一种可移动的无屏蔽磁心电图系统。
Sci Adv. 2023 Mar 29;9(13):eadg1746. doi: 10.1126/sciadv.adg1746.

本文引用的文献

1
DETECTION OF THE MAGNETIC FIELD OF THE HEART.心脏磁场的检测
Am Heart J. 1963 Jul;66:95-6. doi: 10.1016/0002-8703(63)90075-9.
2
3
Possible sources of new information in the magnetocardiogram.心磁图中潜在的新信息来源。
J Theor Biol. 1982 Apr 21;95(4):721-9. doi: 10.1016/0022-5193(82)90350-2.
4
The four-electrode resistivity technique as applied to cardiac muscle.
IEEE Trans Biomed Eng. 1982 Jul;29(7):541-6. doi: 10.1109/tbme.1982.324927.
6
A bidomain model for anisotropic cardiac muscle.
Ann Biomed Eng. 1983;11(3-4):191-206. doi: 10.1007/BF02363286.
10
Forward and inverse potential field solutions for cardiac strands of cylindrical geometry.
IEEE Trans Biomed Eng. 1985 Aug;32(8):566-77. doi: 10.1109/TBME.1985.325481.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验