Color Doppler detection of multiple ventricular septal defects.

作者信息

Ludomirsky A, Huhta J C, Vick G W, Murphy D J, Danford D A, Morrow W R

出版信息

Circulation. 1986 Dec;74(6):1317-22. doi: 10.1161/01.cir.74.6.1317.

DOI:10.1161/01.cir.74.6.1317
PMID:3779917
Abstract

Combined two-dimensional and Doppler echocardiography has a high sensitivity and specificity for detection of isolated perimembranous ventricular septal defects. However, muscular or multiple ventricular septal defects may be difficult to diagnose with noninvasive methods, particularly in older children, necessitating angiography for accurate diagnosis. Detection of single and multiple ventricular septal defects with two-dimensional color flow mapping was compared with detection by standard two-dimensional imaging and Doppler. Both techniques were compared with four-chamber left ventricular angiography. Fifty-one patients (age 3 months to 25 years, mean 5.6 years) were studied. Eighteen had solitary ventricular septal defects, 18 had multiple ventricular septal defects, and 15 patients with intact ventricular septum served as a control group. At least one ventricular septal defect was detected by color Doppler and two-dimensional/Doppler methods in all patients with ventricular septal defect proved by angiography with no false positives. In the detection of multiple ventricular septal defects, the sensitivity of color Doppler was 72% and that of two-dimensional/Doppler was 38% (100% specificity in both). Color Doppler failed to identify multiple ventricular septal defects in five patients (two weighing less than 4 kg and three with reduced pulmonary blood flow). However, no large additional muscular defects were missed by imaging and color Doppler. Color Doppler is useful for the detection of ventricular septal defects and has higher sensitivity than two-dimensional/Doppler for multiple ventricular septal defects. The contribution of color Doppler appears to be in the detection of additional small muscular ventricular septal defects.

摘要

相似文献

1
Color Doppler detection of multiple ventricular septal defects.
Circulation. 1986 Dec;74(6):1317-22. doi: 10.1161/01.cir.74.6.1317.
2
Prospective detection by Doppler color flow imaging of additional defects in infants with a large ventricular septal defect.通过多普勒彩色血流成像对大型室间隔缺损婴儿的其他缺损进行前瞻性检测。
J Am Coll Cardiol. 1990 Jun;15(7):1637-42. doi: 10.1016/0735-1097(90)92840-x.
3
Two-dimensional Doppler color flow mapping for detecting atrial and ventricular septal defects. Studies in an animal model and in the clinical setting.
Herz. 1987 Jun;12(3):212-6.
4
Assessment of muscular ventricular septal defect closure by transcatheter or surgical approach: a three-dimensional echocardiographic study.经导管或手术途径闭合肌部室间隔缺损的评估:一项三维超声心动图研究
Eur J Echocardiogr. 2002 Sep;3(3):185-91. doi: 10.1053/euje.2002.0143.
5
[An imaging and color echo-Doppler study of interventricular defects].[室间隔缺损的影像学与彩色超声多普勒研究]
Rev Esp Cardiol. 1993 Nov;46(11):721-6.
6
Two-dimensional and color Doppler assessment of ventricular septal defect of congenital origin.先天性室间隔缺损的二维及彩色多普勒评估
Am J Cardiol. 1989 May 1;63(15):1112-6. doi: 10.1016/0002-9149(89)90088-x.
7
Pulsed Doppler echocardiographic evaluation of ventricular septal defect patches.
Circulation. 1984 Sep;70(3 Pt 2):I38-46.
8
Two-dimensional Doppler color flow mapping in congenital heart disease.先天性心脏病的二维多普勒彩色血流图
Clin Cardiol. 1986 Dec;9(12):591-6. doi: 10.1002/clc.4960091201.
9
Quantification of the area and shunt volume of multiple, circular, and noncircular ventricular septal defects: A 2D/3D echocardiography comparison and real time 3D color Doppler feasibility determination study.多个圆形及非圆形室间隔缺损面积与分流容积的定量分析:二维/三维超声心动图对比及实时三维彩色多普勒可行性判定研究
Echocardiography. 2018 Jan;35(1):90-99. doi: 10.1111/echo.13742. Epub 2017 Oct 29.
10
[Detection and localization of the ventricular septum defect using color Doppler echocardiography. Sensitivity, specificity, limitations].[使用彩色多普勒超声心动图检测和定位室间隔缺损。敏感性、特异性、局限性]
Z Kardiol. 1989 Mar;78(3):187-96.

引用本文的文献

1
Techniques and results in the management of multiple muscular trabecular ventricular septal defects.多发性肌小梁型室间隔缺损的治疗技术与结果
Gen Thorac Cardiovasc Surg. 2013 Jul;61(7):367-75. doi: 10.1007/s11748-013-0267-8. Epub 2013 Jun 5.
2
Preoperative evaluation and surgery in isolated ventricular septal defects: a 21 year perspective.孤立性室间隔缺损的术前评估与手术:21年的回顾
Heart. 2000 Feb;83(2):198-204. doi: 10.1136/heart.83.2.198.
3
The natural history of ventricular septal defects.室间隔缺损的自然病史。
Arch Dis Child. 1999 Nov;81(5):413-6. doi: 10.1136/adc.81.5.413.
4
Colour flow imaging in the diagnosis of multiple ventricular septal defects.彩色血流成像在多发性室间隔缺损诊断中的应用
Br Heart J. 1989 Jul;62(1):43-9. doi: 10.1136/hrt.62.1.43.
5
Potential value of intraoperative Doppler colour flow mapping in operations for complex intracardiac shunting.术中多普勒彩色血流图在复杂心内分流手术中的潜在价值。
Br Heart J. 1989 Dec;62(6):467-9. doi: 10.1136/hrt.62.6.467.
6
Sensitivity and speed of colour Doppler flow mapping compared with continuous wave Doppler for the detection of ventricular septal defects.彩色多普勒血流图与连续波多普勒在检测室间隔缺损方面的敏感性和速度比较。
Br Heart J. 1991 Apr;65(4):201-3. doi: 10.1136/hrt.65.4.201.