Suppr超能文献

多焦点人工晶状体患者老视矫正镜对 Humphrey 视野检查的影响。

Effect of presbyopic correction lens on humphrey visual field testing in patients with multifocal intraocular lens.

机构信息

Department of Ophthalmology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand.

Department of Ophthalmology, Phramongkutklao College of Medicine, Bangkok, Thailand.

出版信息

Medicine (Baltimore). 2023 Oct 13;102(41):e35544. doi: 10.1097/MD.0000000000035544.

Abstract

Most previous studies on the effects of multifocal intraocular lenses (MIOL) on Humphrey visual field (HVF) used presbyopic corrective lens (PC). There has been insufficient data from patients with MIOL performing HVF with and without PC. This study aimed to determine the effect of PC on HVF testing in patients with MIOL. This was a prospective, comparative crossover study at the Department of Ophthalmology, Faculty of Medicine, Siriraj Hospital, Mahidol University between June 2015 and July 2018. Early-stage glaucomatous and non-glaucomatous pseudophakic patients with 2 models of MIOL completed HVF testing with and without PC. Mean deviation (MD), pattern standard deviation (PSD), and reliability indices (fixation losses, false positives, and false negatives) were compared. Ninety-four eyes of 59 patients were enrolled. After excluding patients with confirmed unreliable visual field, 82 eyes of 51 patients (male, 22; female, 29) with a mean age of 65.4 years were included in the study. Forty-nine eyes were non-glaucoma and 33 eyes were early-stage glaucoma. Forty-four eyes received TECNIS ZM900 and 38 eyes received Acrysof IQ ReSTOR SN6AD1. The overall MD standard deviation was -3.5 (2.1) with PC and -3.1 (2.1) without PC (P = .01). The overall PSD standard deviation was 2.8 (1.5) with PC and 2.7 (1.5) without PC (P = .93). The reliability indices were not statistically significantly different with and without PC. There was a good intraclass correlation (ICC) of MD (ICC = 0.87) and PSD (ICC = 0.88) with and without PC. Eyes with TECNIS ZM 900 had significantly better MD when performing HVF without PC (mean difference -0.7, P < .01), but not with Acrysof IQ ReSTOR SN6AD1 (mean difference -0.1, P = .74). Pseudophakic eyes with MIOL may not require PC during HVF testing regardless of the MIOL model. Although eyes with TECNIS ZM900 performed HVF without PC resulted in a significantly better MD value compared with PC, the difference was not clinically significant.

摘要

大多数关于多焦点人工晶状体(MIOL)对 Humphrey 视野(HVF)影响的先前研究都使用了矫正老视的镜片(PC)。目前,对于 MIOL 患者在使用和不使用 PC 时进行 HVF 检查的数据还不够充分。本研究旨在确定 PC 对 MIOL 患者 HVF 检查的影响。这是 2015 年 6 月至 2018 年 7 月在玛希隆大学 Siriraj 医院医学院眼科进行的一项前瞻性、比较性交叉研究。早期青光眼和非青光眼的假性近视患者,分别使用两种 MIOL 模型完成了有和无 PC 的 HVF 检查。比较了平均偏差(MD)、模式标准差(PSD)和可靠性指数(固视丢失、假阳性和假阴性)。59 名患者的 94 只眼入组。排除了确认不可靠的视野的患者后,本研究共纳入了 51 名患者(男性 22 名,女性 29 名)82 只眼(65.4 岁)。49 只眼为非青光眼,33 只眼为早期青光眼。44 只眼接受了 Tecnis ZM900 治疗,38 只眼接受了 Acrysof IQ ReSTOR SN6AD1 治疗。有 PC 时总体 MD 标准差为-3.5(2.1),无 PC 时为-3.1(2.1)(P=0.01)。有 PC 时总体 PSD 标准差为 2.8(1.5),无 PC 时为 2.7(1.5)(P=0.93)。有和无 PC 时的可靠性指数没有统计学差异。MD(ICC=0.87)和 PSD(ICC=0.88)在有和无 PC 时的组内相关性良好。在不使用 PC 进行 HVF 检查时,Tecnis ZM900 组的 MD 明显更好(平均差值-0.7,P<0.01),但 Acrysof IQ ReSTOR SN6AD1 组没有差异(平均差值-0.1,P=0.74)。无论 MIOL 模型如何,MIOL 后的假性近视眼在进行 HVF 检查时可能不需要 PC。尽管 Tecnis ZM900 组在不使用 PC 进行 HVF 检查时 MD 值明显优于 PC,但差异无临床意义。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/60db/10578709/21780584b40b/medi-102-e35544-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验