Ansu Baidoo Velarie Y, Cara Kelly C, Dickinson Stephanie L, Brown Andrew W, Wallace Taylor C, Chung Mei, Gletsu-Miller Nana
Northwestern University Feinberg School of Medicine, Chicago, IL, United States.
Friedman School of Nutrition Science and Policy, Tufts University, Boston, MA, United States.
J Nutr. 2023 Dec;153(12):3458-3471. doi: 10.1016/j.tjnut.2023.10.006. Epub 2023 Oct 14.
There is a lack of consensus on a reference range for ionized magnesium (iMg) in blood as a measure of the status of circulating iMg for the screening of populations.
We estimated the reference range of iMg levels for healthy adult populations and the ranges for populations with cardiovascular disease (CVD), type 2 diabetes, hypertension, and renal disease. We also estimated 95% ranges for circulating magnesium (Mg) in healthy and those with cardiometabolic diseases.
We searched Ovid MEDLINE, Cochrane Central Register of Controlled Trials, and Embase through 24 July, 2020 to identify articles. We included English, peer-reviewed, randomized controlled trials, prospective and retrospective cohort studies, case-control studies, and cross-sectional studies that measured iMg in blood or circulating Mg at baseline. The protocol was registered on PROSPERO (CRD42020216100). Estimated ranges were calculated by employing a frequentist random-effects model using extracted (or calculated) means and SDs from each included study. We determined the 95% confidence interval of the pooled mean.
A total of 95 articles were included with 53 studies having data for healthy participants and 42 studies having data for participants with cardiometabolic diseases. The estimated reference range for iMg for healthy populations was 0.40-0.68 mmol/L, 0.38-0.64 mmol/L for CVD, 0.34-0.66 mmol/L for type 2 diabetes, 0.39-1.04 mmol/L for hypertension, and 0.40-0.76 mmol/L for renal disease. For circulating Mg, the estimated range was 0.72-1.0 mmol/L for healthy adults, 0.56-1.05 mmol/L for CVD, 0.58-1.14 mmol/L for type 2 diabetes, 0.60-1.08 mmol/L for hypertension, and 0.59-1.26 mmol/L for renal disease.
Estimated reference ranges for cardiometabolic disease states for both iMg and circulating Mg were broad and overlapped with the estimated range for healthy populations (0.40-0.68 mmol/L). Further studies should evaluate whether iMg can be used as a biomarker of cardiometabolic disease.
对于血液中离子镁(iMg)的参考范围,目前尚无共识,而该参考范围可作为筛查人群中循环iMg状态的指标。
我们估计了健康成年人群的iMg水平参考范围,以及患有心血管疾病(CVD)、2型糖尿病、高血压和肾病的人群的iMg水平参考范围。我们还估计了健康人群和患有心脏代谢疾病人群的循环镁(Mg)的95%参考范围。
我们检索了截至2020年7月24日的Ovid MEDLINE、Cochrane对照试验中心注册库和Embase,以识别相关文章。我们纳入了英文、经同行评审的随机对照试验、前瞻性和回顾性队列研究、病例对照研究以及横断面研究中在基线时测量血液中iMg或循环Mg的研究。该方案已在PROSPERO(CRD42020216100)上注册。通过使用从每个纳入研究中提取(或计算)的均值和标准差,采用频率学派随机效应模型计算估计范围。我们确定了合并均值的95%置信区间。
共纳入95篇文章,其中53项研究有健康参与者的数据,42项研究有心脏代谢疾病参与者的数据。健康人群iMg的估计参考范围为0.40 - 0.68 mmol/L,CVD为0.38 - 0.64 mmol/L,2型糖尿病为0.34 - 0.66 mmol/L,高血压为0.39 - 1.04 mmol/L,肾病为0.40 - 0.76 mmol/L。对于循环Mg,健康成年人的估计范围为0.72 - 1.0 mmol/L,CVD为0.56 - 1.05 mmol/L,2型糖尿病为0.58 - 1.14 mmol/L,高血压为0.60 - 1.08 mmol/L,肾病为0.59 - 1.26 mmol/L。
iMg和循环Mg在心脏代谢疾病状态下的估计参考范围较宽,且与健康人群的估计范围(0.40 - 0.68 mmol/L)重叠。进一步的研究应评估iMg是否可作为心脏代谢疾病的生物标志物。