Ramm Maximiliano, Alarcón-Zapata Bárbara, Monsalves Juan, Bustamante Luis
Departamento de Análisis Instrumental, Facultad de Farmacia, Universidad de Concepción, Concepción 4030000, Chile.
Foods. 2023 Oct 20;12(20):3851. doi: 10.3390/foods12203851.
The INFOGEST protocol has been widely used as a static simulation of gastrointestinal food digestion for bioaccessibility assessments on bioactive compounds. The standardization of the activity of several enzymes, such as pepsin, via UV-spectrophotometry of digested hemoglobin at 280 nm is a key step in the protocol. Standardization is a crucial stage since it is necessary to determine the quantity of enzyme to be added to the sample for digestion. However, this method is yet to be analytically validated; it requires quartz cuvettes and large volumes of samples and is time-consuming. Thus, we reviewed and adapted a well-known colorimetric method in microplates array by using the Folin-Ciocalteu reagent, and this study is the first to report for miniaturization of this method, the advantages of which include its automation, ease of use, the low volume of samples required, the minimal use of reagents, and speed. This method was compared to the traditional UV method, and the comparison results show no statistical difference between the inter day means for each group ( > 0.05). The proposed method was validated, showing high reproducibility (8% as inter-day CV) and statistically comparable results with the traditional UV spectrophotometric method.
INFOGEST方案已被广泛用作胃肠道食物消化的静态模拟,用于生物活性化合物的生物可及性评估。通过在280nm处对消化后的血红蛋白进行紫外分光光度法对几种酶(如胃蛋白酶)的活性进行标准化是该方案的关键步骤。标准化是一个关键阶段,因为有必要确定添加到样品中用于消化的酶的量。然而,该方法尚未经过分析验证;它需要石英比色皿和大量样品,且耗时。因此,我们通过使用福林-酚试剂对微孔板阵列中的一种著名比色法进行了回顾和改进,本研究首次报道了该方法的小型化,其优点包括自动化、易用性、所需样品量少、试剂用量最少和速度快。将该方法与传统紫外方法进行比较,比较结果显示每组日间平均值之间无统计学差异(>0.05)。所提出的方法经过验证,具有高重现性(日间CV为8%),且与传统紫外分光光度法的结果具有统计学可比性。