Suppr超能文献

评估菲律宾用于动物死后狂犬病诊断的侧向流动设备:一项多中心研究。

Evaluation of lateral flow devices for postmortem rabies diagnosis in animals in the Philippines: a multicenter study.

机构信息

Department of Agriculture, Bureau of Animal Industry , Quezon, Philippines.

Department of Microbiology, Faculty of Medicine, Oita University , Yufu, Oita, Japan.

出版信息

J Clin Microbiol. 2023 Dec 19;61(12):e0084223. doi: 10.1128/jcm.00842-23. Epub 2023 Nov 22.

Abstract

Expansion of the use of lateral flow devices (LFD) for animal rabies diagnosis can help mitigate the widespread underreporting of rabies. However, this has been hindered by the limited number and small sample size of previous studies. To overcome this limitation, we conducted a multicenter study with a larger sample size to assess the diagnostic accuracy of the ADTEC LFD for postmortem rabies diagnosis in animals. Thirteen governmental animal diagnostic laboratories in the Philippines were involved in this study, and 791 animals suspected of having rabies were tested using both the direct fluorescence antibody test (DFAT) and ADTEC LFD between August 2021 and October 2022. The LFD demonstrated a sensitivity of 96.3% [95% confidence interval (CI): 94.1%-97.9%] and a specificity of 99.7% (95% CI: 98.4%-100%). Notably, false-negative results were more likely to occur in laboratories with lower annual processing volumes of rabies samples in the previous years (adjusted odds ratio 4.97, 95% CI: 1.49-16.53). In this multicenter study, the high sensitivity and specificity of the LFD for the diagnosis of animal rabies, compared to that of the DFAT, was demonstrated, yet concerns regarding false-negative results remain. In areas with limited experience in processing rabies samples, it is essential to provide comprehensive training and careful attention during implementation.

摘要

扩大侧向流动检测设备(LFD)在动物狂犬病诊断中的应用,可以帮助减轻狂犬病广泛漏报的问题。然而,由于之前研究的数量有限且样本量较小,这一目标受到了阻碍。为了克服这一限制,我们进行了一项具有更大样本量的多中心研究,以评估 ADTEC LFD 在动物死后狂犬病诊断中的诊断准确性。菲律宾的 13 家政府动物诊断实验室参与了这项研究,在 2021 年 8 月至 2022 年 10 月期间,使用直接荧光抗体试验(DFAT)和 ADTEC LFD 对 791 例疑似患有狂犬病的动物进行了检测。LFD 的敏感性为 96.3%(95%置信区间:94.1%-97.9%),特异性为 99.7%(95%置信区间:98.4%-100%)。值得注意的是,在前几年每年处理狂犬病样本量较低的实验室中,假阴性结果更有可能发生(调整后的优势比 4.97,95%置信区间:1.49-16.53)。在这项多中心研究中,与 DFAT 相比,LFD 对动物狂犬病的诊断具有较高的敏感性和特异性,但仍存在假阴性结果的担忧。在处理狂犬病样本经验有限的地区,提供全面的培训和实施过程中的仔细关注至关重要。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/e8e2/10729751/602f542f7b92/jcm.00842-23.f001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验