Department of Orthodontics, School of Dentistry, Faculty of Health Sciences, Aristotle University of Thessaloniki, Thessaloniki, Greece; Department of Orthodontics, School of Dental Medicine, Case Western Reserve University, Cleveland, OH, USA.
Department of Orthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece.
Int Orthod. 2024 Mar;22(1):100840. doi: 10.1016/j.ortho.2023.100840. Epub 2024 Jan 12.
The aim of this study is to compare the accuracy of cone beam computed tomography (CBCT) for dental model scanning to the accuracy of model scanners.
Subjects from private practice were collected and scanned according to specific selection criteria. A total of 10 STL files were produced and used as reference files. They were printed with a three-dimensional (3D) printer and then scanned with CBCT and model scanner. For trueness evaluation, all models were scanned once with both equipments. Each file derived from each scan was compared with the corresponding reference model file. For the precision measurements, the physical model from the first master reference model file was scanned 10 times with each equipment and compared with the reference STL file. A reverse engineering software was used for all 3D best-fit comparisons.
With regard to the measurement of trueness of each method, the calculated mean root mean square (RMS) value was 0.06±0.01mm for the CBCT, and 0.15±0.02mm for the model scanner. There was a significant difference between the two methods (P<0.01). For the evaluation of precision of each scanner, the mean RMS value was 0.0056±0.001mm for the CBCT, and 0.153±0.002mm for model scanner. There was a significant difference between the two methods (P<0.01).
Cone Beam Computed Tomography seems to be an accurate method for scanning dental models. CBCT performs better than model scanners to scan dental models in terms of trueness and precision.
本研究旨在比较锥形束 CT(CBCT)对牙模扫描的准确性与模型扫描仪的准确性。
从私人诊所收集受试者,并根据特定的选择标准进行扫描。共制作了 10 个 STL 文件,并用作参考文件。它们使用三维(3D)打印机打印,然后使用 CBCT 和模型扫描仪进行扫描。为了评估准确性,两种设备都对所有模型进行了一次扫描。每个扫描文件都与相应的参考模型文件进行比较。为了进行精度测量,每个设备对第一个主参考模型文件的物理模型进行了 10 次扫描,并与参考 STL 文件进行比较。使用逆向工程软件进行所有 3D 最佳拟合比较。
就每种方法的准确性测量而言,CBCT 的计算平均均方根(RMS)值为 0.06±0.01mm,模型扫描仪的 RMS 值为 0.15±0.02mm。两种方法之间存在显著差异(P<0.01)。对于每个扫描仪的精度评估,CBCT 的平均 RMS 值为 0.0056±0.001mm,模型扫描仪的 RMS 值为 0.153±0.002mm。两种方法之间存在显著差异(P<0.01)。
锥形束 CT 似乎是一种扫描牙模的准确方法。在准确性和精度方面,CBCT 优于模型扫描仪扫描牙模。