Suppr超能文献

克罗恩病中匐行脂肪的CT能谱参数及其与炎症活动的相关性

CT energy spectral parameters of creeping fat in Crohn's disease and correlation with inflammatory activity.

作者信息

Li Xianchu, Wu Wei, Yuan Yan, Zhu Zhiming, Liu Xiaowei, Xiao Desheng, Long Xueying

机构信息

Department of Radiology, The Second Affiliated Hospital, Hengyang Medical School, University of South China, Hengyang, China.

Department of Radiology, Xiangya Hospital, Central South University, 87 Xiangya Road, Changsha, 410008, China.

出版信息

Insights Imaging. 2024 Jan 17;15(1):10. doi: 10.1186/s13244-023-01592-6.

Abstract

OBJECTIVES

Creeping fat is a kind of unique abnormal mesenteric tissue at the sites of diseased bowel of Crohn's disease. By using dual-energy CT enterography, this study aimed to evaluate the feasibility of spectral parameters in the quantitative analysis of mesenteric adipose tissue or creeping fat.

METHODS

In this study, patients with known or suspected Crohn's disease who underwent dual-energy CT enterography from March 1, 2019, to March 31, 2021, were enrolled. Among them, 40 patients with surgery and pathology-proven creeping fat were selected as the creeping fat Crohn's disease group, and 40 normal patients were selected as the control group. The quantitative spectral parameters including the slope of the Hounsfield unit curve, normalised fat-water concentration, normalised fat-iodine concentration, and normalised fat volume fraction at the enteric phases were obtained. Mann-Whitney U test, Kruskal-Wallis H test, and receiver operating characteristic curve analysis were applied to compare quantitative parameters among various groups.

RESULTS

A significant difference was observed in the slope of the Hounsfield unit curve, normalised fat-water concentration, normalised fat-iodine concentration, and normalised fat volume fraction between mesenteric adipose tissue and creeping fat with Crohn's disease at the enteric phase (all p < 0.001). The slope of the Hounsfield unit curve of creeping fat at the enteric phase had a better capability to distinguish inactive and active Crohn's disease (AUC = 0.93, p < 0.001).

CONCLUSION

Dual-energy CT enterography with quantitative spectral parameters is a potentially novel noninvasive tool for evaluating creeping fat in Crohn's disease.

CRITICAL RELEVANCE STATEMENT

Energy spectral parameters of creeping fat in Crohn's disease are significantly different from normal mesenteric adipose tissues and are correlated with inflammatory activity.

KEY POINTS

• Dual-energy CT enterography allows quantitatively assessing creeping fat with spectral parameters. • The creeping fat has distinct spectral parameters to normal mesenteric adipose. • The spectral parameters accurately differentiate active and inactive Crohn's disease.

摘要

目的

匐行脂肪是克罗恩病病变肠段一种独特的异常肠系膜组织。本研究旨在通过双能CT小肠造影评估光谱参数在肠系膜脂肪组织或匐行脂肪定量分析中的可行性。

方法

本研究纳入了2019年3月1日至2021年3月31日期间接受双能CT小肠造影的已知或疑似克罗恩病患者。其中,40例经手术及病理证实有匐行脂肪的患者被选为匐行脂肪型克罗恩病组,40例正常患者被选为对照组。获取了包括肠期亨氏单位曲线斜率、归一化脂肪-水浓度、归一化脂肪-碘浓度和归一化脂肪体积分数在内的定量光谱参数。应用曼-惠特尼U检验、克鲁斯卡尔-沃利斯H检验和受试者工作特征曲线分析来比较各组间的定量参数。

结果

在肠期,肠系膜脂肪组织与克罗恩病匐行脂肪之间的亨氏单位曲线斜率、归一化脂肪-水浓度、归一化脂肪-碘浓度和归一化脂肪体积分数存在显著差异(均p < 0.001)。肠期匐行脂肪的亨氏单位曲线斜率在区分非活动期和活动期克罗恩病方面具有更好的能力(AUC = 0.93,p < 0.001)。

结论

具有定量光谱参数的双能CT小肠造影是评估克罗恩病匐行脂肪的一种潜在新型无创工具。

关键相关性声明

克罗恩病匐行脂肪的能谱参数与正常肠系膜脂肪组织有显著差异,且与炎症活动相关。

要点

• 双能CT小肠造影可通过光谱参数定量评估匐行脂肪。• 匐行脂肪与正常肠系膜脂肪具有不同的光谱参数。• 光谱参数能准确区分活动期和非活动期克罗恩病。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/e55f/10792149/bb7125b1a21f/13244_2023_1592_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验