Department of Civil Engineering, Ege University, Izmir, Turkey.
Department of Civil Engineering, Izmir Demokrasi University, Izmir, Turkey.
Environ Sci Pollut Res Int. 2024 Feb;31(8):12340-12350. doi: 10.1007/s11356-024-31926-w. Epub 2024 Jan 17.
In the departments of civil engineering, many experiments are conducted in laboratories for educational and research purposes. Varying degrees of respirable dust are generated as the outcome of these experiments, which could cause harm to instructors' and students' health. This study is devised to highlight the importance of indoor air quality in university laboratories. As part of the research, four different particulate matter (PM) sizes (PM, PM, PM, and PM) were measured during specific experiments-sieve analysis, preparation of the concrete mixture, crushing aggregate by jaw crusher, dynamic triaxial compression test, sieve analysis of silt specimen, cleaning sieve by an air compressor, and proctor compaction test-being conducted periodically in the laboratories of civil engineering departments. The measured values are mainly high compared to indoor air quality standards. Mitigation strategies were applied to reduce indoor air PM levels in the three experiments that contained the highest PM levels. The results have shown that mitigation strategies applied as control measures could make a remarkable difference in protecting instructors and civil engineering students.
在土木工程系,许多实验都是在实验室进行的,目的是教育和研究。这些实验会产生不同程度的可吸入粉尘,可能会对教师和学生的健康造成危害。本研究旨在强调大学实验室室内空气质量的重要性。作为研究的一部分,在土木工程系的实验室中,周期性地进行了四项不同的颗粒物(PM)大小(PM、PM、PM 和 PM)的测量实验-筛分析、混凝土混合物的制备、颚式破碎机破碎骨料、动态三轴压缩试验、淤泥试样的筛分析、空气压缩机清洁筛子以及 Proctor 压实试验。测量值主要高于室内空气质量标准。在包含最高 PM 水平的三个实验中,应用了减轻策略来降低室内空气 PM 水平。结果表明,作为控制措施的减轻策略可以显著改善保护教师和土木工程学生的效果。