Shenzhen Third People's Hospital, National Clinical Research Center for Infectious Disease, 518112, Shenzhen, China.
Shanghai Key Laboratory of Atmospheric Particle Pollution Prevention (LAP3), Department of Environmental Science & Engineering, Fudan University, 200438, Shanghai, China.
BMC Infect Dis. 2024 Jan 23;24(1):122. doi: 10.1186/s12879-024-09020-w.
The Xpert MTB/RIF test (Xpert) can help in the accurate screening of tuberculosis, however, its widespread use is limited by its high cost and lack of accessibility. Pooling of sputum samples for testing is a strategy to cut expenses and enhance population coverage but may result in a decrease in detection sensitivity due to the dilution of Mycobacterium tuberculosis (Mtb) by sample mixing. We investigated how the mixing ratio affected the detection performance of Xpert. We used frozen sputum samples that had been kept after individual Xpert assays of the sputa from Mtb-confirmed TB patients and non-TB patients. Our results showed that the overall sensitivity of the Xpert pooling assay remained higher than 80% when the mixing ratio was between 1/2 and 1/8. When the mixing ratio was raised to 1/16, the positive detection rate fell to 69.0%. For patients with either a high sputum Mtb smear score ≥ 2, a time-to-positive culture ≤ 10 days, or an Xpert test indicating a high or medium abundance of bacteria, the pooling assay positivity rates were 93.3%, 96.8%, and 100% respectively, even at a 1/16 mixing ratio. For participants with cavities and cough, the pooling assay positivity rates were 86.2% and 90.0% at a 1/8 ratio, higher than for those without these signs. Our results show that the Xpert pooled assay has a high overall sensitivity, especially for highly infectious patients. This pooling strategy with lower reagent and labor costs could support TB screening in communities with limited resources, thereby facilitating reductions in the community transmission and incidence of TB worldwide.
Xpert MTB/RIF 检测(Xpert)有助于结核病的准确筛查,但其广泛应用受到成本高和不可及性的限制。痰标本混合检测是一种降低成本和提高人群覆盖率的策略,但由于样本混合导致结核分枝杆菌(Mtb)稀释,可能会降低检测灵敏度。我们研究了混合比例如何影响 Xpert 的检测性能。我们使用了冷冻痰标本,这些标本是在 Mtb 确诊的结核病患者和非结核病患者的个体 Xpert 检测后保留的。我们的结果表明,当混合比例在 1/2 到 1/8 之间时,Xpert 混合检测的总灵敏度仍保持在 80%以上。当混合比例提高到 1/16 时,阳性检出率降至 69.0%。对于涂片 Mtb 评分≥2、培养阳性时间≤10 天或 Xpert 检测显示细菌含量高或中量的患者,混合检测的阳性率分别为 93.3%、96.8%和 100%,即使在 1/16 的混合比例下也是如此。对于有空洞和咳嗽的参与者,在 1/8 的比例下,混合检测的阳性率分别为 86.2%和 90.0%,高于没有这些迹象的参与者。我们的结果表明,Xpert 混合检测具有很高的总灵敏度,尤其是对于传染性强的患者。这种使用较少试剂和劳动力成本的混合策略可以支持资源有限的社区进行结核病筛查,从而有助于减少全球社区传播和结核病发病率。