Mori Hitoshi, Hamabe Akira, Kawano Daisuke, Naganuma Tsukasa, Tahara Mai, Gatate Yodo, Kimura Toyokazu, Tabata Hirotsugu, Kato Ritsushi
Department of Cardiology Japan Self Defense Forces Central Hospital Tokyo Japan.
Department of Cardiology Saitama Medical University, International Medical Center Hidaka Japan.
J Arrhythm. 2023 Dec 29;40(1):83-89. doi: 10.1002/joa3.12981. eCollection 2024 Feb.
The role of the pulmonary veins (PVs) as triggers in atrial fibrillation (AF) is well-known; however, their detailed electrophysiological properties have not been thoroughly examined.
This study aimed to investigate the electrophysiological properties of the PVs between paroxysmal AF (pAF) and persistent AF (perAF).
Prior to catheter ablation in patients with pAF ( = 51) and perAF ( = 41), a voltage map of the left atrium and PVs was created under sinus rhythm, and the area of the myocardial sleeves in the PVs and their electrophysiological characteristics, including the pacing threshold and effective refractory period (ERP), were compared between the two groups.
Compared with perAF, the myocardial sleeves of PVs for pAF were significantly larger for all PVs. The ERP for perAF was significantly shorter than that for pAF for all PVs. The pacing threshold for perAF was significantly higher than that for pAF for the right and left superior PVs.
In patients with perAF, a decrease in the normal myocardial sleeves and a shortening of the ERP were observed for all PVs. Those changes in the electrophysiological properties of the PVs might be related to the persistence of AF.
肺静脉(PVs)作为心房颤动(AF)触发因素的作用已广为人知;然而,其详细的电生理特性尚未得到充分研究。
本研究旨在探讨阵发性房颤(pAF)和持续性房颤(perAF)患者肺静脉的电生理特性。
在51例pAF患者和41例perAF患者进行导管消融术前,在窦性心律下创建左心房和肺静脉的电压图,并比较两组患者肺静脉心肌袖的面积及其电生理特性,包括起搏阈值和有效不应期(ERP)。
与perAF相比,pAF患者所有肺静脉的心肌袖均显著更大。所有肺静脉的perAF的ERP均显著短于pAF。右肺上静脉和左肺上静脉的perAF起搏阈值显著高于pAF。
在perAF患者中,所有肺静脉均观察到正常心肌袖减少和ERP缩短。肺静脉电生理特性的这些变化可能与房颤的持续存在有关。