Waddell Alexander, Birkett Stefan, Broom David, McGregor Gordon, Harwood Amy E
Centre for Physical Activity, Sport & Exercise Science, Institute of Health & Wellbeing, Coventry University, UK.
Department of Sport and Exercise Sciences, Institute of Sport, Manchester Metropolitan University, UK.
J Sci Med Sport. 2024 May;27(5):314-318. doi: 10.1016/j.jsams.2024.01.007. Epub 2024 Jan 25.
Commercially available wearable activity monitors can promote physical activity behaviour. Clinical trials typically quantify physical activity with research grade activity monitors prior to testing interventions utilising commercially available wearable activity monitors aimed at increasing step count. Therefore, it is important to test the agreement of these two types of activity monitors.
Observational.
Thirty adults (20-65 years, n = 19 females) were provided a Fitbit Charge 4©. To determine reliability using an intraclass correlation coefficient, two, one-minute bouts of treadmill walking were performed at a self-selected pace. Subsequently, participants wore both an ActiGraph wGT3X-BT and the Fitbit for seven days. To determine agreement, statistical equivalence and the mean absolute percentage error were calculated and represented graphically with a Bland-Altman plot. Ordinary least products regression was performed to identify fixed or proportional bias.
The Fitbit showed 'good' step count reliability on the treadmill (intraclass correlation coefficient = 0.75, 95 % CI = 0.53-0.87, p < 0.001). In free-living however, it overestimated step count when compared to the ActiGraph wGT3X-BT (mean absolute percentage error = 26.02 % ± 14.63). Measurements did not fall within the ± 10 % equivalence region and proportional bias was apparent (slope 95 % CI = 1.09-1.35).
The Fitbit Charge 4© is reliable when measuring step count on a treadmill. However, there is an overestimation of daily steps in free-living environments which may falsely indicate compliance with physical activity recommendations.
市面上可买到的可穿戴活动监测器能够促进身体活动行为。在使用旨在增加步数的市售可穿戴活动监测器测试干预措施之前,临床试验通常使用研究级活动监测器对身体活动进行量化。因此,测试这两种类型活动监测器的一致性很重要。
观察性研究。
为30名成年人(20 - 65岁,n = 19名女性)提供了一台Fitbit Charge 4©。为了使用组内相关系数确定可靠性,以自选速度在跑步机上进行了两组、每组一分钟的步行测试。随后,参与者佩戴ActiGraph wGT3X - BT和Fitbit七天。为了确定一致性,计算了统计等效性和平均绝对百分比误差,并用布兰德 - 奥特曼图以图形方式表示。进行了普通最小乘积回归以识别固定或比例偏差。
Fitbit在跑步机上显示出“良好”的步数可靠性(组内相关系数 = 0.75,95% CI = 0.53 - 0.87,p < 0.001)。然而,在自由生活状态下,与ActiGraph wGT3X - BT相比,它高估了步数(平均绝对百分比误差 = 26.02% ± 14.63)。测量值未落在±10%的等效区域内,并且比例偏差明显(斜率95% CI = 1.09 - 1.35)。
Fitbit Charge 4©在测量跑步机上的步数时是可靠的。然而,在自由生活环境中,每日步数存在高估情况,这可能会错误地表明符合身体活动建议。