Suppr超能文献

预热和持续加热对Triton™与Twin Kleen™组织溶解能力的影响:一项研究。

Effect of prewarming and continuous warming on tissue dissolving ability of Triton™ versus Twin Kleen™: An study.

作者信息

Deepa Velagala Lakshmi, Vanga Himasai Reddy, Kadali Naveena, Divve Sravyasai, Sravya Vemana, Kapa Roopa Sravya

机构信息

Department of Conservative Dentistry and Endodontics, Lenora Institute of Dental Sciences, Rajanagaram, Andhra Pradesh, India.

出版信息

J Conserv Dent Endod. 2024 Jan;27(1):100-104. doi: 10.4103/JCDE.JCDE_201_23. Epub 2024 Jan 13.

Abstract

CONTEXT

TwinKleen™ and Triton™ are newer all-in-one irrigants that have simultaneous action on both organic and inorganic contents. Studies comparing their tissue dissolving ability (TDA) either at room temperature (RT) or on prewarming (PW) and continuous warming (CW) are not yet reported.

AIMS

To evaluate and compare the effect of 3% sodium hypochlorite (NaOCl), Twin Kleen™, and Triton™, on the bovine TDA.

MATERIALS AND METHODS

One hundred and twenty tissue specimens (size 4 mm × 4 mm × 2 mm and weight 37 ± 3 mg) were divided into Group 1, normal saline (negative control); Group 2, 3% NaOCl (positive control); Group 3, Twin Kleen™; and Group 4, Triton™ ( = 30) Each group is further divided into three subgroups with ten samples each as sub group a - at room temperature (RT), sub group b - on pre warming (PW) and sub group c- on continuous warming (CW), Tissue specimens were immersed in test tubes with 5 ml of respective irrigants replenished thrice every 15 min. The percentage difference in tissue weights was calculated after 5, 10, and 15 min.

STATISTICAL ANALYSIS USED

Multiple intergroup comparisons were done using Tukey's multiple-comparison test, using SPSS software version 23.0.

RESULTS

Both Triton™ and 3% NaOCl showed significantly higher dissolution than normal saline and Twin Kleen™ on CW followed by PW than at RT. Twin Kleen™ showed significantly less dissolution at all the tested temperatures.

CONCLUSIONS

Heating enhances the TDA of Triton™ and 3% NaOCl but not Twin Kleen™. CW showed significantly higher dissolution than PW.

摘要

背景

TwinKleen™和Triton™是新型的一体化冲洗剂,对有机和无机成分均有同时作用。尚未有研究报告比较它们在室温(RT)、预热(PW)和持续加热(CW)条件下的组织溶解能力(TDA)。

目的

评估并比较3%次氯酸钠(NaOCl)、Twin Kleen™和Triton™对牛组织溶解能力的影响。

材料与方法

120个组织样本(尺寸为4mm×4mm×2mm,重量为37±3mg)分为第1组,生理盐水(阴性对照);第2组,3% NaOCl(阳性对照);第3组,Twin Kleen™;第4组,Triton™(每组n = 30)。每组进一步分为三个亚组,每个亚组有10个样本,分别为亚组a - 室温(RT)、亚组b - 预热(PW)和亚组c - 持续加热(CW)。将组织样本浸入装有5ml相应冲洗剂的试管中,每15分钟补充三次。在5、10和15分钟后计算组织重量的百分比差异。

统计分析方法

使用SPSS 23.0软件,采用Tukey多重比较检验进行多组间比较。

结果

在持续加热(CW)后再预热(PW)的情况下,Triton™和3% NaOCl的溶解能力均显著高于生理盐水和Twin Kleen™,在室温(RT)下最低。在所有测试温度下,Twin Kleen™的溶解能力均显著较低。

结论

加热可增强Triton™和3% NaOCl的组织溶解能力,但对Twin Kleen™无效。持续加热(CW)的溶解能力显著高于预热(PW)。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/dadc/10880472/990604a181b6/JCDE-27-100-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验