Epidemiol Infect. 2024 Mar 4;152:e53. doi: 10.1017/S0950268824000256.
In February 2021, a cluster of Beta variant (B.1.351) coronavirus disease 2019 (COVID-19) cases were identified in an apartment building located in Northern Ontario, Canada. Most cases had no known contact with each other. Objectives of this multi-component outbreak investigation were to better understand the social and environmental factors that facilitated the transmission of COVID-19 through this multi-unit residential building (MURB). A case-control study examined building-specific exposures and resident behaviours that may have increased the odds of being a case. A professional engineer assessed the building's heating, ventilation, and air-conditioning (HVAC) systems. Whole-genome sequencing and an in-depth genomic analysis were performed. Forty-five outbreak-confirmed cases were identified. From the case-control study, being on the upper floors (OR: 10.4; 95% CI: 1.63-66.9) and within three adjacent vertical lines (OR: 28.3; 3.57-225) were both significantly associated with being a case of COVID-19, after adjusting for age. There were no significant differences in reported behaviours, use of shared spaces, or precautions taken between cases and controls. An assessment of the building's ventilation found uncontrolled air leakage between apartment units. A single genomic cluster was identified, where most sequences were identical to one another. Findings from the multiple components of this investigation are suggestive of aerosol transmission between units.
2021 年 2 月,在加拿大安大略省北部的一栋公寓楼中发现了一群 Beta 变异株(B.1.351)的 2019 冠状病毒疾病(COVID-19)病例。大多数病例彼此之间没有已知的接触。本多组分暴发调查的目的是更好地了解促进 COVID-19 通过多单元住宅(MURB)传播的社会和环境因素。病例对照研究检查了可能增加在建筑物中感染 COVID-19 几率的特定建筑物暴露和居民行为。一位专业工程师评估了建筑物的供暖、通风和空调(HVAC)系统。进行了全基因组测序和深入的基因组分析。确定了 45 例暴发确诊病例。从病例对照研究来看,在上层(OR:10.4;95%CI:1.63-66.9)和相邻的三个垂直线上(OR:28.3;3.57-225)的人感染 COVID-19 的几率明显更高,在调整年龄后。病例和对照组之间在报告的行为、共用空间的使用或采取的预防措施方面没有显著差异。对建筑物通风的评估发现公寓单元之间存在不受控制的空气泄漏。确定了一个单一的基因组簇,其中大多数序列彼此相同。这项调查的多个组成部分的结果表明,单元之间存在气溶胶传播。