Suppr超能文献

慢性踝关节不稳患者反应性平衡测试的重测信度、评定者内信度和评定者间信度

Test-retest, intra- and inter-rater reliability of the reactive balance test in patients with chronic ankle instability.

作者信息

Maricot Alexandre, Lathouwers Elke, Verschueren Jo, De Pauw Kevin, Meeusen Romain, Roelands Bart, Tassignon Bruno

机构信息

Human Physiology and Sports Physiotherapy Research Group, Faculty of Physical Education and Physiotherapy, Vrije Universiteit Brussel, Brussels, Belgium.

Brussels Human Robotics Research Center (BruBotics), Vrije Universiteit Brussel, Brussels, Belgium.

出版信息

Front Neurol. 2024 Feb 16;15:1320043. doi: 10.3389/fneur.2024.1320043. eCollection 2024.

Abstract

INTRODUCTION

The Reactive Balance Test (RBT) could be a valuable addition to research on chronic ankle instability (CAI) and clinical practice, but before it can be used in clinical practice it needs to be reliable. It has already been proven reliable in healthy recreational athletes, but not yet in patients with CAI who have shown persistent deficits in dynamic balance. The study aimed to determine the test-retest, intra-, and inter-rater reliability of the RBT in patients with CAI, and the test-retest and inter-rater reliability of the newly developed RBT score sheet.

METHODS

We used a repeated-measures, single-group design to administer the RBT to CAI patients on three occasions, scored by multiple raters. We included 27 participants with CAI. The study used multiple reliability measures, including Pearson r, intra-class correlations (ICC), standard error of measurement (SEM), standard error of prediction (SEP), minimal detectable change (MDC), and Bland-Altman plots, to evaluate the reliability of the RBT's outcome measures (visuomotor response time and accuracy). It also assessed the test-retest and inter-rater reliability of the RBT score sheet using the same measures.

RESULTS

The ICC measures for test-retest reliability were similar for accuracy (0.609) and VMRT (0.594). Intra-rater reliability had high correlations and ICCs for accuracy ( = 0.816, ICC = 0.815) and VMRT ( = 0.802, ICC = 0.800). Inter-rater reliability had a higher ICC for VMRT (0.868) than for accuracy (0.690).

CONCLUSION

Test-retest reliability was moderate, intra-rater reliability was good, and inter-rater reliability showed moderate reliability for accuracy and good reliability for VMRT. Additionally, the RBT shows robust SEM and mean difference measures. The score sheet method also demonstrated moderate test-retest reliability, while inter-rater reliability was good to excellent. This suggests that the RBT can be a valuable tool in assessing and monitoring balance in patients with CAI.

摘要

引言

反应性平衡测试(RBT)可能是慢性踝关节不稳(CAI)研究及临床实践中的一项有价值的补充,但在用于临床实践之前,它需要具备可靠性。该测试在健康的业余运动员中已被证明具有可靠性,但在动态平衡方面持续存在缺陷的CAI患者中尚未得到验证。本研究旨在确定RBT在CAI患者中的重测信度、内部评分者信度和外部评分者信度,以及新开发的RBT评分表的重测信度和外部评分者信度。

方法

我们采用重复测量单组设计,对27名CAI患者进行三次RBT测试,由多名评分者进行评分。本研究使用了多种可靠性测量方法,包括Pearson相关系数r、组内相关系数(ICC)、测量标准误(SEM)、预测标准误(SEP)、最小可检测变化(MDC)和Bland-Altman图,以评估RBT结果测量指标(视觉运动反应时间和准确性)的可靠性。同时,使用相同的测量方法评估RBT评分表的重测信度和外部评分者信度。

结果

准确性(0.609)和视觉运动反应时间(VMRT,0.594)的重测信度ICC测量值相似。内部评分者信度方面,准确性(r = 0.816,ICC = 0.815)和VMRT(r = 0.802,ICC = 0.800)具有较高的相关性和ICC值。外部评分者信度方面,VMRT的ICC(0.868)高于准确性(0.690)。

结论

重测信度中等,内部评分者信度良好,外部评分者信度在准确性方面为中等可靠性,在VMRT方面为良好可靠性。此外,RBT显示出稳健的SEM和均值差异测量。评分表方法也显示出中等的重测信度,而外部评分者信度良好至优秀。这表明RBT可以成为评估和监测CAI患者平衡功能的有价值工具。