Suppr超能文献

评估胸椎旋转活动度测量方法的有效性:磁共振成像与临床测量的比较

Assessing validity of thoracic spine rotation range of motion measurement methods: comparison of magnetic resonance imaging and clinical measurements.

作者信息

Ichikawa Kazuna, Otsuka Takuya, Abduh Hardianty Andi Munawarah, Kuruma Hironobu

机构信息

Department of Physical Therapy, Tokyo Metropolitan University: 7-2-10 Higashiogu, Arakawa-ku, Tokyo 116-8551, Japan.

出版信息

J Phys Ther Sci. 2024 Mar;36(3):95-101. doi: 10.1589/jpts.36.95. Epub 2024 Mar 1.

Abstract

[Purpose] This work was designed to establish criteria for assessing common clinical measurement methods for thoracic spinal rotation angles by comparing their results with magnetic resonance imaging measurements. [Participants and Methods] Twenty-six healthy participants underwent thoracic rotation angle assessments using an electronic goniometer in three positions: lumbar-locked, seated, and half-kneeling. We compared these results with measurements obtained by magnetic resonance imaging. [Results] A moderate but significant positive correlation was observed between the thoracic rotation angle measured by magnetic resonance imaging and the lumbar-locked rotation test. The respective 95% confidence intervals of these correlation coefficients were 0.09 and 0.72. Bland-Altman analysis revealed a fixed error in the lumbar-locked rotation test, suggesting that the test tended to overestimate thoracic rotation compared with magnetic resonance imaging, but proportional errors could not be definitively identified. [Conclusions] Thoracic spine rotation angles measured using magnetic resonance imaging aligned closely with previously reported results. Notably, although measurements obtained by the lumbar-locked rotation test correlated with magnetic resonance imaging results, they exhibited fixation errors. Functional tests (seated and half-kneeling) showed limited correlations with magnetic resonance imaging results. The influence of adjacent joints on clinical measurements should be considered.

摘要

[目的] 本研究旨在通过将胸段脊柱旋转角度的常见临床测量方法的结果与磁共振成像测量结果进行比较,建立评估这些方法的标准。[参与者与方法] 26名健康参与者在三个体位下使用电子测角仪进行胸段旋转角度评估:腰部固定、坐位和半跪位。我们将这些结果与磁共振成像获得的测量结果进行比较。[结果] 磁共振成像测量的胸段旋转角度与腰部固定旋转试验之间观察到中度但显著的正相关。这些相关系数各自的95%置信区间为0.09和0.72。Bland-Altman分析显示腰部固定旋转试验存在固定误差,表明该试验与磁共振成像相比倾向于高估胸段旋转,但无法明确确定比例误差。[结论] 使用磁共振成像测量的胸段脊柱旋转角度与先前报道的结果密切一致。值得注意的是,尽管腰部固定旋转试验获得的测量结果与磁共振成像结果相关,但它们存在固定误差。功能试验(坐位和半跪位)与磁共振成像结果的相关性有限。应考虑相邻关节对临床测量的影响。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/351d/10904216/4fc34a9f7ab6/jpts-36-095-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验