Suppr超能文献

Evaluation of H2O2 prophylaxis of bacteriuria in patients with long-term indwelling Foley catheters: a randomized controlled study.

作者信息

Sweet D E, Goodpasture H C, Holl K, Smart S, Alexander H, Hedari A

出版信息

Infect Control. 1985 Jul;6(7):263-6. doi: 10.1017/s0195941700061725.

Abstract

Since the long-term catheterized patient is at significant risk of urinary tract infection, and the catheter drainage bags of these patients are at significant risk of becoming reservoirs for nosocomial pathogens, we carried out a randomized, controlled study to determine the efficacy of intermittent drainage bag instillation of hydrogen peroxide (H2O2) in patients requiring indwelling Foley catheters for 5 days or more. Herein we report the effects of this technique on the rates of catheter and bag bacteriuria, the duration to positive culture, the temporal relationships observed, and the spectrum of organisms recovered. Bag source bacteriuria was found with the same frequency in both control and H2O2 groups. H2O2 did reduce contamination of the drainage bag but did not reduce catheter-associated bacteriuria or frequency of symptomatic urinary tract infection. Furthermore, H2O2 did not reduce the frequency of bag contamination with most of the common nosocomial urinary pathogens.