Liu Wenxiao, Zhang Kun, Cheng Jing, Yu Shiqiang, Cheng Chunjie, Jiang Bo, Zhou Linyi, Li Yongqing
Institute of Animal Husbandry and Veterinary Medicine, Beijing Academy of Agriculture and Forestry Sciences, Beijing, China.
Research Center for Infectious Diseases in Livestock and Poultry, Beijing Academy of Agricultural and Forestry Sciences, Beijing, China.
Front Microbiol. 2024 Feb 29;15:1371849. doi: 10.3389/fmicb.2024.1371849. eCollection 2024.
Bovine herpes virus 1 (BoHV-1) causes a wide variety of diseases in wild and domestic cattle. The most widely used method for viral identification is real-time PCR, which can only be performed in laboratories using sophisticated instruments by expert personnel. Herein, we developed an ultrasensitive time-resolved fluorescence lateral flow immunochromatographic strip (ICS) assay for detecting BoHV-1 in bovine samples using a monoclonal antibody against BoHV-1 labelled with fluorescent microspheres, which can be applied in any setting. The intact process from sample collection to final result can be achieved in 15 min. The limit of detection of the assay for BoHV-1 was 10 TCID/100 μL. The coincidence rate of the ICS method and real-time PCR recommended by the World Organization for Animal Health (WOAH) was 100% for negative, 92.30% for positive, and 95.42% for total, as evaluated by the detection of 131 clinical samples. This detection method was specifically targeted to BoHV-1, not exhibiting cross-reactivity with other bovine pathogens including BoHV-5. We developed an ICS assay equipped with a portable instrument that offers a sensitive and specific platform for the rapid and reliable detection of BoHV-1 in the field. The Point-of-Care test of BoHV-1 is suitable for the screening and surveillance of BoHV-1 in dairy herds.
牛疱疹病毒1型(BoHV-1)可在野生和家养牛中引发多种疾病。目前应用最广泛的病毒鉴定方法是实时荧光定量PCR,但该方法只能由专业人员在配备精密仪器的实验室中进行操作。在此,我们研发了一种超灵敏的时间分辨荧光侧向流动免疫层析试纸条(ICS)检测方法,用于检测牛样本中的BoHV-1。该方法使用了标记有荧光微球的抗BoHV-1单克隆抗体,可在任何环境下使用。从样本采集到得出最终结果的整个过程仅需15分钟。该检测方法对BoHV-1的检测限为10 TCID/100 μL。通过对131份临床样本进行检测评估,ICS方法与世界动物卫生组织(WOAH)推荐的实时荧光定量PCR方法的阴性符合率为100%,阳性符合率为92.30%,总符合率为95.42%。该检测方法特异性针对BoHV-1,与包括BoHV-5在内的其他牛病原体无交叉反应。我们开发了一种配备便携式仪器的ICS检测方法,为在现场快速、可靠地检测BoHV-1提供了一个灵敏且特异的平台。BoHV-1的即时检测适用于奶牛场中BoHV-1的筛查和监测。