[《听觉表现类别-II及婴幼儿有意义听觉整合量表在葡萄牙语欧洲地区的适应性及有效性研究:用于人工耳蜗植入儿童》]

[Adaptation and Validation for European Portuguese of the Auditory Performance Categories-II and Infant-Toddler Meaningful Auditory Integration Scale for Children with Cochlear Implant].

作者信息

Roque Reis Luí S, Gani Kaamil, Peres Carlota, Nunes Gonçalo, Santos Ricardo, O'Neill Assunção, Escada Pedro

机构信息

Serviço de Otorrinolaringologia. Hospital Egas Moniz. Centro Hospitalar de Lisboa Ocidental (CHLO). Lisboa; NOVA Medical School. Faculdade de Ciências Médicas. Lisboa. Portugal.

Serviço de Otorrinolaringologia. Hospital Egas Moniz. Centro Hospitalar de Lisboa Ocidental (CHLO). Lisboa. Portugal.

出版信息

Acta Med Port. 2024 May 2;37(5):334-341. doi: 10.20344/amp.20169. Epub 2024 Mar 18.

Abstract

INTRODUCTION

The Categories of Auditory Performance II (CAP-II) scale and the Infant-Toddler Meaningful Audit Integration Scale (IT-MAIS) are simple and quick questionnaires that allow assessment of the auditory performance of children with cochlear implant (CI). The aim of this study was to translate, adapt and validate the European Portuguese version of the CAP-II and IT-MAIS scales.

METHODS

A total of 85 participants completed the European Portuguese version of the CAP-II and IT-MAIS questionnaires, of which 45 were parents of children with pediatric cochlear implants (9.84 ± 4.22 years) and another 40 were parents of children with normal hearing (8.35 ± 3.56 years). Inter-rater reproducibility, test-retest reproducibility, comparison of study group versus control group results, internal consistency and correlation of the new scales were evaluated.

RESULTS

The CAP-II and IT-MAIS scales showed high reliability and reproducibility, respectively, with an intraclass correlation coefficient (ICC) of 0.979 (p < 0.001) and a Spearman's correlation of 0.924 for the CAP-II scale, and an ICC of 0.932 (p < 0.001) and Spearman's correlation coefficient of 0.732 for the IT-MAIS scale. The IT-MAIS and CAP-II versions showed strong internal consistency (Cronbach's α coefficient value of 0.887 for the CAP-II scale and Spearman's positive correlation of 0.677 for the IT-MAIS scale, respectively) and allowed for the differentiation between children with normal hearing and post-implantation children (p = 0.001 and p < 0.001 respectively for each of the scales). There was no association between parental education and the results on the scales (p > 0.05).

CONCLUSION

The findings demonstrated that the European Portuguese version of these scales is a valid and reliable tool for assessing auditory performance in European Portuguese-speaking children with hearing loss.

摘要

引言

听觉表现分类II(CAP-II)量表和婴幼儿有意义听觉整合量表(IT-MAIS)是简单快捷的问卷,可用于评估人工耳蜗植入(CI)儿童的听觉表现。本研究的目的是翻译、改编并验证CAP-II和IT-MAIS量表的欧洲葡萄牙语版本。

方法

共有85名参与者完成了CAP-II和IT-MAIS问卷的欧洲葡萄牙语版本,其中45名是小儿人工耳蜗植入儿童的家长(年龄9.84±4.22岁),另外40名是听力正常儿童的家长(年龄8.35±3.56岁)。评估了评分者间的可重复性、重测可重复性、研究组与对照组结果的比较、新量表的内部一致性和相关性。

结果

CAP-II和IT-MAIS量表分别显示出高可靠性和可重复性,CAP-II量表的组内相关系数(ICC)为0.979(p<0.001),Spearman相关性为0.924;IT-MAIS量表的ICC为0.932(p<0.001),Spearman相关系数为0.732。IT-MAIS和CAP-II版本显示出很强的内部一致性(CAP-II量表的Cronbach'sα系数值为0.887,IT-MAIS量表的Spearman正相关性为0.677),并能够区分听力正常儿童和植入后儿童(各量表分别为p=0.001和p<0.001)。父母教育程度与量表结果之间无关联(p>0.05)。

结论

研究结果表明,这些量表的欧洲葡萄牙语版本是评估欧洲葡萄牙语听力损失儿童听觉表现的有效且可靠的工具。