To systematically analyze the accuracy of ultrasonic techniques in assessing the nature of gastric contents and their volume.
English-language articles that used ultrasonic techniques to assess the nature of gastric contents and their volume in patients were selected. In eligible studies, data were recalculated and analyzed for forest plots and subject summary curves of operating characteristics (SROC). Study quality was assessed using the diagnostic accuracy study quality assessment tool QUADAS-2. Publication bias was tested using funnel plots.
Nine articles with a total of 523 study subjects were identified for this review. All studies were feasibility studies. The sensitivity of ultrasound assessment of gastric contents ranged from 53 to 100% and the specificity from 48 to 99%. The combined analysis yielded an area under the working characteristic curve for subjects of 97% (95% confidence interval (CI), 95-98%), a sensitivity of 95% (95% CI, 84-99%), and a specificity of 88% (95% CI, 72-95%). There was a high degree of heterogeneity among the studies due to inter-operator differences and small sample sizes.
Ultrasound techniques have high diagnostic accuracy in assessing the nature of gastric contents and their volume in patients. However, most of the studies were feasibility studies with small sample sizes, lacked standardization, and had high risk of bias. More studies are needed in the future to investigate the diagnostic performance of gastric ultrasound assessment techniques.
Ultrasonography can be used to assess gastric contents, but standardized data integration and reporting are needed to account for the diagnostic capabilities of this technology.
• Ultrasound is a safe and feasible tool for assessing gastric contents. • Ultrasound has good diagnostic performance for gastric contents. • There is still a certain heterogeneity within our analysis process; more research is needed in the future to improve our results.
系统分析超声技术评估胃内容物性质及其容量的准确性。
选取使用超声技术评估患者胃内容物性质及其容量的英文文章。在符合条件的研究中,重新计算数据并分析森林图和受试者工作特征总结曲线(SROC)。使用诊断准确性研究质量评估工具QUADAS - 2评估研究质量。使用漏斗图检验发表偏倚。
本综述共纳入9篇文章,涉及523名研究对象。所有研究均为可行性研究。超声评估胃内容物的敏感性为53%至100%,特异性为48%至99%。综合分析得出受试者工作特征曲线下面积为97%(95%置信区间(CI),95 - 98%),敏感性为95%(95%CI,84 - 99%),特异性为88%(95%CI,72 - 95%)。由于操作者之间的差异和样本量小,研究之间存在高度异质性。
超声技术在评估患者胃内容物性质及其容量方面具有较高的诊断准确性。然而,大多数研究是样本量较小的可行性研究,缺乏标准化,且偏倚风险高。未来需要更多研究来调查胃超声评估技术的诊断性能。
超声可用于评估胃内容物,但需要标准化的数据整合和报告以说明该技术的诊断能力。
• 超声是评估胃内容物的安全可行工具。• 超声对胃内容物具有良好的诊断性能。• 在我们的分析过程中仍存在一定的异质性;未来需要更多研究来改善我们的结果。