Suppr超能文献

宏基因组学和病原体靶向新一代测序技术在成人脑膜炎和脑炎诊断中的评估:中国一项多中心前瞻性观察队列研究

Evaluation of metagenomic and pathogen-targeted next-generation sequencing for diagnosis of meningitis and encephalitis in adults: A multicenter prospective observational cohort study in China.

作者信息

Chen Weibi, Liu Gang, Cui Lili, Tian Fei, Zhang Jiatang, Zhao Jiahua, Lv Ying, Du Jianxin, Huan Xinyu, Wu Yingfeng, Zhang Yan

机构信息

Department of Neurology, Xuanwu Hospital, Capital Medical University, Beijing, China.

Department of Neurology, the First Medical Center of People's Liberation Army General Hospital, Beijing, China.

出版信息

J Infect. 2024 May;88(5):106143. doi: 10.1016/j.jinf.2024.106143. Epub 2024 Mar 26.

Abstract

BACKGROUND

Next-generation sequencing (NGS) might aid in the identification of causal pathogens. However, the optimal approaches applied to cerebrospinal fluid (CSF) for detection are unclear, and studies evaluating the application of different NGS workflows for the diagnosis of intracranial infections are limited.

METHODS

In this multicenter, prospective observational cohort study, we described the diagnostic efficacy of pathogen-targeted NGS (ptNGS) and metagenomic NGS (mNGS) compared to that of composite microbiologic assays, for infectious meningitis/encephalitis (M/E).

RESULTS

In total, 152 patients diagnosed with clinically suspected M/E at four tertiary hospitals were enrolled; ptNGS and mNGS were used in parallel for pathogen detection in CSF. Among the 89 patients who were diagnosed with definite infectious M/E, 57 and 39 patients had causal microbial detection via ptNGS and mNGS, respectively. The overall accuracy of ptNGS was 65.1%, with a positive percent agreement (PPA) of 64% and a negative percent agreement (NPA) of 66.7%; and the overall accuracy of mNGS was 47.4%, with a PPA of 43.8% and an NPA of 52.4% after discrepancy analysis. There was a significant difference in the detection efficiency between these two methods both for PPA (sensitivity) and overall accuracy for pathogen detection (P < 0.05).

CONCLUSIONS

NGS tests have provided new information in addition to conventional microbiologic tests. ptNGS seems to have superior performance over mNGS for common causative pathogen detection in CSF for infectious M/E.

摘要

背景

下一代测序(NGS)可能有助于鉴定致病病原体。然而,应用于脑脊液(CSF)检测的最佳方法尚不清楚,评估不同NGS工作流程在颅内感染诊断中应用的研究也很有限。

方法

在这项多中心、前瞻性观察队列研究中,我们描述了与复合微生物检测相比,病原体靶向NGS(ptNGS)和宏基因组NGS(mNGS)对感染性脑膜炎/脑炎(M/E)的诊断效能。

结果

共纳入了四家三级医院152例临床疑似M/E的患者;ptNGS和mNGS并行用于CSF中的病原体检测。在89例确诊为明确感染性M/E的患者中,分别有57例和39例通过ptNGS和mNGS检测到致病微生物。ptNGS的总体准确率为65.1%,阳性百分一致性(PPA)为64%,阴性百分一致性(NPA)为66.7%;mNGS的总体准确率为47.4%,差异分析后PPA为43.8%,NPA为52.4%。两种方法在PPA(敏感性)和病原体检测总体准确率方面的检测效率均存在显著差异(P<0.05)。

结论

除了传统微生物检测外,NGS检测提供了新的信息。在感染性M/E的CSF常见致病病原体检测中,ptNGS似乎比mNGS具有更好的性能。