Abstract

Objectives In this study, we outline our rationale for delivering a dose of ≥15 Gy in stereotactic radiosurgery (SRS) of glomus jugulare tumor (GJT) while ensuring the avoidance of complications associated with doses >13 Gy to the facial nerve. To avoid such complications, we initially utilized the Gamma Knife Perfexion (GK) system (Elekta Instrument AB, Stockholm, Sweden) at our institution but encountered challenges related to lengthy treatment times and difficulty in sculpting doses to minimize doses to spare the facial nerve. As a potential solution, we propose the use of HyperArc (Varian Medical Systems, Palo Alto, CA), a newly developed automated delivery platform for linear accelerator (LINAC)-based SRS. HyperArc offers the potential for faster treatment and more complex shaping of the radiotherapy dose with multiple arcs and multi-leaf collimators. Methods We retrospectively reviewed nine cases of patients with GJT treated with HyperArc. Patients' demographic and treatment data were collected. Additionally, simulated GK treatment plans were created and compared with HyperArc plans to assess time savings, PTV coverage, and plan quality. Results One male and eight female patients, with a mean age of 63.9 years, were included. Treatments were delivered on average in 29 minutes, achieving 95-100% of the tumor while limiting the facial nerve to <13 Gy. Treatments replanned using our GK system could achieve only 92-99% tumor coverage while respecting facial nerve constraints, with average treatment times of 180 minutes. Comparable plan quality parameters were attained with both modalities. Conclusions The HyperArc system provides a qualitatively satisfactory and rapid treatment delivery of a highly sculpted radiotherapy dose to maximize tumor coverage and minimize facial nerve complications.

摘要

目的 在本研究中,我们概述了在颈静脉球瘤(GJT)的立体定向放射外科治疗(SRS)中给予≥15 Gy剂量的基本原理,同时确保避免与面神经剂量>13 Gy相关的并发症。为避免此类并发症,我们机构最初使用伽玛刀Perfexion(GK)系统(瑞典斯德哥尔摩的医科达仪器公司),但遇到了治疗时间长以及难以雕刻剂量以尽量减少对面神经的剂量等挑战。作为一种潜在的解决方案,我们建议使用HyperArc(美国加利福尼亚州帕洛阿尔托的瓦里安医疗系统公司),这是一种新开发的基于直线加速器(LINAC)的SRS自动输送平台。HyperArc具有实现更快治疗以及利用多弧和多叶准直器对放射治疗剂量进行更复杂塑形的潜力。方法 我们回顾性分析了9例接受HyperArc治疗的GJT患者。收集了患者的人口统计学和治疗数据。此外,创建了模拟的GK治疗计划,并与HyperArc计划进行比较,以评估时间节省情况、计划靶体积(PTV)覆盖情况和计划质量。结果 纳入1例男性和8例女性患者,平均年龄63.9岁。平均治疗时间为29分钟,肿瘤覆盖率达到95 - 100%,同时将面神经剂量限制在<13 Gy。使用我们的GK系统重新规划的治疗在遵守面神经限制的情况下,肿瘤覆盖率仅为92 - 99%,平均治疗时间为180分钟。两种方式获得的计划质量参数相当。结论 HyperArc系统能够以定性上令人满意的方式快速输送高度塑形的放射治疗剂量,以最大化肿瘤覆盖率并最小化面神经并发症。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/64f4/10977903/debde5c9376d/cureus-0016-00000055070-i01.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验