Suppr超能文献

不同浸泡时间下经次氯酸钠消毒的牙胶尖的拉伸强度和弹性模量:一项比较研究

Tensile Strength and Elastic Modulus of Gutta-percha Cones Disinfected with Sodium Hypochlorite at Different Immersion Times: An Comparative Study.

作者信息

Bellido-Guzmán Rolando, Ladera-Castañeda Marysela, Castro-Pérez Vargas Antonieta M, López-Gurreonero Carlos, Cornejo-Pinto Alberto, Aliaga-Mariñas Ana, Cervantes-Ganoza Luis A, Cayo-Rojas César F

机构信息

Faculty of Dentistry and Postgraduate School, Universidad Nacional Federico Villarreal, Grupo de Investigación Salud y Bienestar Global, Lima, Peru.

School of Stomatology, Universidad Cientifica del Sur, Lima, Peru.

出版信息

J Int Soc Prev Community Dent. 2024 Jan 4;14(1):69-77. doi: 10.4103/jispcd.jispcd_106_22. eCollection 2024 Jan-Feb.

Abstract

AIM

The tensile strength and modulus of elasticity of gutta-percha cones can be chemically altered due to disinfectant solutions. Therefore, the aim of the present study was to compare tensile strength and elastic modulus of gutta-percha cones subjected to sodium hypochlorite (NaOCl) disinfection at different times.

MATERIALS AND METHODS

This and longitudinal experimental study consisted of 45 gutta-percha cones, divided equally into three groups: Group 1 (disinfection with 2.5% NaOCl), Group 2 (disinfection with 5.25% NaOCl), and control group. All groups were subdivided according to immersion times for 1, 5, and 10 minutes. Tensile strength and elastic modulus were measured with a universal testing machine. For comparing more than two independent groups, parametric analysis of variance test with Sheffe's post hoc was used and for multivariate analysis, and multivariate analysis of variance test based on Pillai's Trace was used. In all statistical analysis, a significance level ≤ 0.05 was considered.

RESULTS

When comparing the tensile strength of gutta-percha cones, no significant differences were observed after being immersed at 1, 5, and 10 minutes in NaOCl 2.5% ( = 0.715) and 5.25% ( = 0.585). Regarding the elastic modulus, a significant decrease ( < 0.05) was observed in those that were immersed in NaOCl 2.5% and 5.25% for 1, 5, and 10 minutes. Furthermore, increased NaOCl concentration significantly reduced the elastic modulus ( < 0.001). However, there were no significant differences in tensile strength ( > 0.05) and elastic modulus ( > 0.05), when evaluating the interaction between NaOCl concentration and time.

CONCLUSION

Increasing NaOCl concentration significantly reduced the modulus of elasticity without affecting the tensile strength of gutta-percha cones, regardless of immersion time. Furthermore, the interaction of time and NaOCl concentration did not significantly affect the tensile strength and elastic modulus.

摘要

目的

牙胶尖的拉伸强度和弹性模量会因消毒溶液而发生化学改变。因此,本研究的目的是比较在不同时间接受次氯酸钠(NaOCl)消毒的牙胶尖的拉伸强度和弹性模量。

材料与方法

本纵向实验研究包括45个牙胶尖,平均分为三组:第1组(用2.5% NaOCl消毒)、第2组(用5.25% NaOCl消毒)和对照组。所有组再根据浸泡时间分为1分钟、5分钟和10分钟亚组。用万能试验机测量拉伸强度和弹性模量。为比较两个以上独立组,采用带有谢费尔事后检验的参数方差分析进行检验,对于多变量分析,则采用基于皮莱迹的多变量方差分析进行检验。在所有统计分析中,显著性水平设定为≤0.05。

结果

比较牙胶尖的拉伸强度时,在2.5% NaOCl(P = 0.715)和5.25% NaOCl(P = 0.585)中浸泡1分钟、5分钟和10分钟后,未观察到显著差异。关于弹性模量,在2.5%和5.25% NaOCl中浸泡1分钟,5分钟和10分钟的牙胶尖弹性模量显著降低(P < 0.05)。此外,NaOCl浓度增加显著降低了弹性模量(P < 0.001)。然而,在评估NaOCl浓度和时间之间的相互作用时,拉伸强度(P > 0.05)和弹性模量(P > 0.05)没有显著差异。

结论

无论浸泡时间如何,增加NaOCl浓度会显著降低牙胶尖的弹性模量,而不影响其拉伸强度。此外,时间和NaOCl浓度的相互作用对拉伸强度和弹性模量没有显著影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验