Savannah River National Laboratory, 301 Gateway Drive, Aiken, South Carolina 29803, United States.
United States Air Force - Air Force Research Laboratory, 711th Human Performance Wing, 2510 Fifth Street, Area B, Building 840, Wright-Patterson AFB, Ohio 45433, United States.
J Am Soc Mass Spectrom. 2024 May 1;35(5):829-833. doi: 10.1021/jasms.3c00400. Epub 2024 Apr 2.
A new approach using orthogonal analytical techniques is developed for chemical identification. High resolution mass spectrometry and infrared ion spectroscopy are applied through a 5-level confidence paradigm to demonstrate the effectiveness of nontargeted workflow for the identification of hazardous organophosphates. Triphenyl phosphate is used as a surrogate organophosphate for occupational exposure, and silicone wristbands are used to represent personal samplers. Spectral data of a target compound is combined with spectral data of the sodium adduct and quantum chemical calculations to achieve a confirmed identification. Here, we demonstrate a nontargeted workflow that identifies organophosphate exposure and provides a mechanism for selecting validated methods for quantitative analyses.
采用正交分析技术的新方法用于化学鉴定。通过 5 级置信范式应用高分辨率质谱和红外离子光谱学,证明了针对危险有机磷酸酯进行非靶向工作流程识别的有效性。三苯基磷酸盐被用作职业暴露的替代有机磷酸酯,硅树脂手环被用作个人采样器。目标化合物的光谱数据与钠加合物的光谱数据和量子化学计算相结合,以实现确认鉴定。在这里,我们展示了一种非靶向工作流程,可识别有机磷酸酯暴露情况,并为选择经过验证的定量分析方法提供了机制。