Institute of Sport Science and Innovations, Lithuanian Sports University, 44221 Kaunas, Lithuania.
Department of Health Promotion and Rehabilitation, Lithuanian Sports University, 44221 Kaunas, Lithuania.
Sensors (Basel). 2024 Apr 3;24(7):2277. doi: 10.3390/s24072277.
Near-infrared spectroscopy (NIRS) during repeated limb occlusions is a noninvasive tool for assessing muscle oxidative capacity. However, the method's reliability and validity remain under investigation. This study aimed to determine the reliability of the NIRS-derived mitochondrial power of the musculus vastus lateralis and its correlation with whole-body (cycling) aerobic power (V̇O peak). Eleven healthy active men (28 ± 10 y) twice (2 days apart) underwent repeated arterial occlusions to induce changes in muscle oxygen delivery after 15 s of electrical muscle stimulation. The muscle oxygen consumption (mV̇O) recovery time and rate () constants were calculated from the NIRS OHb signal. We assessed the reliability (coefficient of variation and intraclass coefficient of correlation [ICC]) and equivalency (-test) between visits. The results showed high reproducibility for the mV̇O recovery time constant (ICC = 0.859) and moderate reproducibility for the value (ICC = 0.674), with no significant differences between visits ( > 0.05). NIRS-derived did not correlate with the V̇O peak relative to body mass ( = 0.441, = 0.17) or the absolute V̇O peak ( = 0.366, = 0.26). In conclusion, NIRS provides a reproducible estimate of muscle mitochondrial power, which, however, was not correlated with whole-body aerobic capacity in the current study, suggesting that even if somewhat overlapping, not the same set of factors underpin these distinct indices of aerobic capacity at the different (peripheral and whole-body systemic) levels.
近红外光谱(NIRS)在重复肢体闭塞期间是评估肌肉氧化能力的一种非侵入性工具。然而,该方法的可靠性和有效性仍在研究中。本研究旨在确定股外侧肌的 NIRS 衍生线粒体能力的可靠性及其与全身(循环)有氧能力(V̇O 峰值)的相关性。11 名健康活跃的男性(28±10 岁)两次(相隔 2 天)接受重复动脉闭塞,以在 15 秒电肌肉刺激后诱导肌肉氧输送的变化。从 NIRS OHb 信号计算肌肉耗氧量(mV̇O)恢复时间和速率()常数。我们评估了两次访问之间的可靠性(变异系数和组内相关系数 [ICC])和等效性(-检验)。结果表明,mV̇O 恢复时间常数的重现性很高(ICC=0.859),而 值的重现性中等(ICC=0.674),两次访问之间无显着差异(>0.05)。NIRS 衍生的 与相对体重的 V̇O 峰值(=0.441,=0.17)或绝对 V̇O 峰值(=0.366,=0.26)均无相关性。总之,NIRS 可提供肌肉线粒体能力的可重复估计,然而,在当前研究中,与全身有氧能力不相关,这表明即使有一定的重叠,也不是同一组因素支持这些不同的有氧能力指标在不同的(外周和全身系统性)水平上。