Department of Orthopedic Oncology, Aarhus University Hospital, Denmark.
Musculoskeletal Tumor Section of the Department of Orthopedic Surgery, Rigshospitalet - University of Copenhagen, Denmark.
Acta Orthop. 2024 Apr 17;95:174-179. doi: 10.2340/17453674.2024.40502.
Concerns have emerged regarding elevated levels of cobalt and chromium in patients with metal-on-metal megaprostheses. This prospective study aims to identify systemic cobalt and chromium levels in metal-on-polyethylene knee and hip megaprostheses and their associations with other factors.
56 patients underwent knee or hip megaprosthesis surgery at 2 sarcoma centers. Serum cobalt and chromium levels were measured preoperatively and thrice within the first year using inductively coupled plasma mass spectrometry.
A statistically significant difference in serum cobalt levels (1.4 ppb; 95% confidence interval [CI] 0.0-3.3) was observed 1 year after knee megaprosthesis surgery compared with preoperative levels. In contrast no difference in chromium levels was observed after 1 year compared with preoperative levels (0.05 ppb; CI 0.0-0.8). An association between younger age, higher eGFR, and increased cobalt levels was observed. No significant correlations were found between ion levels and resection length or the number of modular connections.
We found elevated serum ion levels in metal-on-polyethylene knee megaprostheses in contrast to metal-on-polyethylene hip megaprostheses. Furthermore, a positive correlation between cobalt and chromium levels, and between cobalt and eGFR was identified, along with a negative correlation between cobalt and age. This study highlights the importance of monitoring systemic cobalt and chromium levels in patients with megaprostheses.
人们对金属对金属型超大假体患者钴和铬水平升高表示担忧。本前瞻性研究旨在确定金属对聚乙烯膝关节和髋关节超大假体的体内钴和铬水平,并分析其与其他因素的相关性。
2 家肉瘤中心的 56 例患者接受了膝关节或髋关节超大假体手术。在术前和术后 1 年内,通过电感耦合等离子体质谱法(inductively coupled plasma mass spectrometry,ICP-MS)分别测量 3 次血清钴和铬水平。
膝关节超大假体手术后 1 年,血清钴水平(1.4 ppb;95%置信区间 [CI] 0.0-3.3)与术前相比存在统计学差异。相比之下,术后 1 年血清铬水平与术前相比无差异(0.05 ppb;CI 0.0-0.8)。年龄较小、eGFR 较高与钴水平升高相关。离子水平与切除长度或模块连接数量之间无显著相关性。
与金属对聚乙烯髋关节超大假体相比,我们发现金属对聚乙烯膝关节超大假体的血清离子水平升高。此外,钴和铬水平之间、钴和 eGFR 之间呈正相关,而钴和年龄之间呈负相关。本研究强调了监测超大假体患者体内钴和铬水平的重要性。