Arkesteyn Anke, Cornelissen Véronique, Steyaert Jean, Claes Jomme, Michielsen Matthijs, Van Damme Tine
Department of Rehabilitation Sciences, KU Leuven, Leuven, Belgium.
Department of Neurosciences, KU Leuven, Leuven, Belgium.
Disabil Rehabil. 2025 Jan;47(2):501-511. doi: 10.1080/09638288.2024.2340704. Epub 2024 Apr 21.
There is a need for valid and reliable clinical assessment tools to assess cardiorespiratory fitness (CRF) levels in adolescents with autism. Therefore, this study aimed to examine the concurrent validity and test-retest reliability of the Astrand-Rhyming Test (ART) in this population.
45 adolescents with autism aged 12-18 years ( = 32 males, 14.47 ± 1.79 years) performed the ART twice (test-retest reliability) and completed a maximal cardiopulmonary exercise test (CPET) (concurrent validity). Reliability parameters included Pearson correlations, intraclass correlation coefficients (ICCs), standard error of measurements (SEM), minimal detectable changes (MDC), coefficients of variation, paired sample t-tests, linear regressions and Bland-Altman plots. The concurrent validity was evaluated with Pearson correlations, ICCs, paired sample t-tests, linear regressions and Bland-Altman plots.
Strong test-retest reliability ( = 0.84-0.85, ICC = 0.84-0.85) was found for the ART, but the wide limits of agreement intervals suggest the presence of substantial variability. The large SEM (4.73-5.08 mL/kg/min) and MDC (13.20-14.07 mL/kg/min) values suggest lower absolute reliability. Moderate to strong levels of association ( = 0.74-0.75) and agreement (ICC = 0.59-0.66) were found between estimated (ART1) and measured (CPET) VO max levels, but significant systematic differences (5.71-8.82 mL/kg/min) were observed.
The ART is an accessible and promising method to monitor submaximal CRF levels over time but is less appropriate to estimate maximal CRF levels in this population.
需要有效且可靠的临床评估工具来评估自闭症青少年的心肺适能(CRF)水平。因此,本研究旨在检验阿斯兰德-莱明测试(ART)在该人群中的同时效度和重测信度。
45名年龄在12至18岁的自闭症青少年(n = 32名男性,14.47 ± 1.79岁)进行了两次ART测试(重测信度),并完成了一次最大心肺运动测试(CPET)(同时效度)。信度参数包括皮尔逊相关性、组内相关系数(ICC)、测量标准误(SEM)、最小可检测变化(MDC)、变异系数、配对样本t检验、线性回归和布兰德-奥特曼图。同时效度通过皮尔逊相关性、ICC、配对样本t检验、线性回归和布兰德-奥特曼图进行评估。
发现ART具有较强的重测信度(r = 0.84 - 0.85,ICC = 0.84 - 0.85),但一致性区间的宽泛范围表明存在较大变异性。较大的SEM(4.73 - 5.08 mL/kg/min)和MDC(13.20 - 14.07 mL/kg/min)值表明绝对信度较低。估计(ART1)和测量(CPET)的最大摄氧量(VO₂max)水平之间存在中度至高度的关联(r = 0.74 - 0.75)和一致性(ICC = 0.59 - 0.66),但观察到显著的系统差异(5.71 - 8.82 mL/kg/min)。
ART是一种可获取且有前景的方法,可长期监测次最大CRF水平,但不太适合估计该人群的最大CRF水平。