Suppr超能文献

肩胛骨运动学的三维测量:评分者间信度以及基于皮肤标记点模型相对于皮质内针模型的验证

Three-dimensional measurements of scapular kinematics: Interrater reliability and validation of a skin marker-based model against an intracortical pin model.

作者信息

Malmberg Catarina, Jensen Stefan E, Michaud Benjamin, Andreasen Kristine R, Hölmich Per, Barfod Kristoffer W, Bencke Jesper

机构信息

Sports Orthopedic Research Center - Copenhagen (SORC-C), Department of Orthopedic Surgery, Copenhagen University Hospital Amager & Hvidovre, Kettegård Allé 30, 2650, Hvidovre, Denmark.

Human Movement Analysis Laboratory, Department of Orthopedic Surgery, Copenhagen University Hospital Amager & Hvidovre, Kettegård Allé 30, 2650, Hvidovre, Denmark.

出版信息

Heliyon. 2024 Apr 9;10(8):e29414. doi: 10.1016/j.heliyon.2024.e29414. eCollection 2024 Apr 30.

Abstract

A skin marker-based motion capture model providing measures of scapular rotations was recently developed. The aim of this study was to investigate the concurrent validity and the interrater reliability of the model. Shoulder range of motion (RoM) and activities of daily living (ADL) were tested in healthy volunteers with reflective markers on the scapula and thorax. To investigate the validity, the model was compared to simultaneous data collection from markers on a scapular intracortical pin. The interrater reliability was tested by comparing the skin marker-based protocol performed by two investigators. The mean root mean square error (RMSE) and the intraclass correlation coefficient (ICC(2,1)) were calculated to determine the validity and the interrater reliability, respectively. Eight subjects were included in the validity test: female/male = 2/6, mean (SD) age 35.0 (3.0) and BMI 23.4 (3.3). The mean RMSE of all scapular rotations ranged 2.3-6.7° during shoulder RoM and 2.4-7.6° during ADL. The highest errors were seen during sagittal and scapular plane flexions, hair combing and eating. The reliability test included twenty subjects: female/male = 8/12, mean (SD) age 31.4 (4.9) and BMI 22.9 (1.7). The ICC(2,1) for measuring protraction ranged 0.07-0.60 during RoM and 0.27-0.69 for ADL, for upward rotation the corresponding ICC(2,1) ranged 0.01-0.64 and 0.38-0.60, and anterior tilt 0.25-0.83 and 0.25-0.62. The validity and interrater reliability of the model are task dependent, and interpretation should be made with caution. The model provides quantitative measurements for objective assessment of scapular movements and can potentially supplement the clinical examination in certain motion tasks.

摘要

最近开发了一种基于皮肤标记的运动捕捉模型,用于测量肩胛骨旋转。本研究的目的是调查该模型的同时效度和评分者间信度。在健康志愿者的肩胛骨和胸部贴上反光标记,测试其肩部活动范围(RoM)和日常生活活动(ADL)。为了研究效度,将该模型与从肩胛骨皮质内针上的标记同时收集的数据进行比较。通过比较两名研究者执行的基于皮肤标记的方案来测试评分者间信度。分别计算平均均方根误差(RMSE)和组内相关系数(ICC(2,1))来确定效度和评分者间信度。效度测试纳入了8名受试者:女性/男性 = 2/6,平均(标准差)年龄35.0(3.0)岁,体重指数23.4(3.3)。在肩部RoM期间,所有肩胛骨旋转的平均RMSE范围为2.3 - 6.7°,在ADL期间为2.4 - 7.6°。在矢状面和肩胛骨平面屈曲、梳头和进食期间误差最高。信度测试纳入了20名受试者:女性/男性 = 8/12,平均(标准差)年龄31.4(4.9)岁,体重指数22.9(1.7)。测量前伸时的ICC(2,1)在RoM期间范围为0.07 - 0.60,在ADL期间为0.27 - 0.69;向上旋转时相应的ICC(2,1)范围为0.01 - 0.64和0.38 - 0.60;前倾时为0.25 - 0.83和0.25 - 0.62。该模型的效度和评分者间信度取决于任务,解释时应谨慎。该模型为肩胛骨运动的客观评估提供了定量测量,并且在某些运动任务中可能补充临床检查。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/4afd/11033140/1b699d57a40a/gr1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验