Abstract

The different tubes affected the tested parameters in different ways. The fibrin and platelet amplitudes are the most sensitive parameters of the RTG-method. A rough surface alterates preferably the platelet activity in the first two milliliters. After about one minute of blood material interaction the amplitudes of fibrin and thrombocytes of all materials have reached the level of the reference blood. The tube with the lowest thrombogenic response to the blood is the polyurethane tube followed by polypropylene, Silastic, polyurethane with the rough surface and finally PVC. In this ex-vivo method the materials are tested under dynamic and nearly physiological conditions. Only one animal is needed for all experiments. No anaesthesia, no anticoagulants are required. The experimental effort and the costs are low. The results are well reproducible although the blood flow might vary slightly. Finally the test results are immediately available.

摘要

不同的试管以不同方式影响所测试的参数。纤维蛋白和血小板振幅是旋转血栓弹力图法最敏感的参数。粗糙表面主要改变前两毫升血液中的血小板活性。血液与材料相互作用约一分钟后,所有材料的纤维蛋白和血小板振幅均达到对照血液的水平。对血液血栓形成反应最低的试管是聚氨酯试管,其次是聚丙烯、硅橡胶、表面粗糙的聚氨酯,最后是聚氯乙烯。在这种体外方法中,材料是在动态且接近生理的条件下进行测试的。所有实验仅需一只动物。无需麻醉,也无需使用抗凝剂。实验工作量和成本较低。尽管血流可能略有变化,但结果具有良好的可重复性。最后,测试结果可立即获得。