Guangzhou Institute of Food Inspection, Guangzhou, 511400, PR China.
Department of Forensic Toxicology, School of Forensic Medicine, Southern Medical University, Guangzhou, 510515, PR China.
Biosens Bioelectron. 2024 Aug 15;258:116357. doi: 10.1016/j.bios.2024.116357. Epub 2024 May 3.
The label probe plays a crucial role in enhancing the sensitivity of lateral flow immunoassays. However, conventional fluorescent microspheres (FMs) have limitations due to their short fluorescence lifetime, susceptibility to background fluorescence interference, and inability to facilitate multi-component detection. In this study, carboxylate-modified Eu(III)-chelate-doped polystyrene nanobeads were employed as label probes to construct a multiple time-resolved fluorescent microsphere-based immunochromatographic test strip (TRFM-ICTS). This novel TRFM-ICTS facilitated rapid on-site quantitative detection of three mycotoxins in grains: Aflatoxin B1 (AFB1), Zearalenone (ZEN), and Deoxynivalenol (DON). The limit of detection (LOD) for AFB1, ZEN, and DON were found to be 0.03 ng/g, 0.11 ng/g, and 0.81 ng/g, respectively. Furthermore, the TRFM-ICTS demonstrated a wide detection range for AFB1 (0.05-8.1 ng/g), ZEN (0.125-25 ng/g), and DON (1.0-234 ng/g), while maintaining excellent selectivity. Notably, the test strip exhibited remarkable stability, retaining its detection capability even after storage at 4 °C for over one year. Importantly, the detection of these mycotoxins relied solely on simple manual operations, and with a portable reader, on-site detection could be accomplished within 20 min. This TRFM-ICTS presents a promising solution for sensitive on-site mycotoxin detection, suitable for practical application in various settings due to its sensitivity, accuracy, simplicity, and portability.
标签探针在增强侧向流动免疫分析的灵敏度方面起着至关重要的作用。然而,由于荧光寿命短、易受背景荧光干扰以及无法促进多组分检测,传统的荧光微球(FM)存在局限性。在本研究中,羧基化 Eu(III)-螯合物掺杂聚苯乙烯纳米珠被用作标记探针,构建了基于多重时间分辨荧光微球的免疫层析测试条(TRFM-ICTS)。这种新型的 TRFM-ICTS 促进了谷物中三种真菌毒素(黄曲霉毒素 B1(AFB1)、玉米赤霉烯酮(ZEN)和脱氧雪腐镰刀菌烯醇(DON))的快速现场定量检测。AFB1、ZEN 和 DON 的检测限(LOD)分别为 0.03 ng/g、0.11 ng/g 和 0.81 ng/g。此外,TRFM-ICTS 对 AFB1(0.05-8.1 ng/g)、ZEN(0.125-25 ng/g)和 DON(1.0-234 ng/g)具有较宽的检测范围,同时保持了出色的选择性。值得注意的是,该测试条具有出色的稳定性,即使在 4°C 下储存一年以上,仍能保持其检测能力。重要的是,这些真菌毒素的检测仅依赖于简单的手动操作,使用便携式读取器,可在 20 分钟内完成现场检测。该 TRFM-ICTS 为敏感的现场真菌毒素检测提供了一种有前途的解决方案,由于其灵敏度、准确性、简单性和便携性,适用于各种实际应用场景。