Suppr超能文献

青光眼患者植入XEN凝胶后角膜曲率读数和前房深度无变化。

No Changes in Keratometry Readings and Anterior Chamber Depth after XEN Gel Implantation in Patients with Glaucoma.

作者信息

Tatti Filippo, Tronci Claudia, Lixi Filippo, Demarinis Giuseppe, Kuzmich Sviatlana, Peiretti Enrico, Fossarello Maurizio, Giannaccare Giuseppe

机构信息

Department of Surgical Sciences, Eye Clinic, University of Cagliari, 09124 Cagliari, Italy.

出版信息

J Clin Med. 2024 Apr 26;13(9):2537. doi: 10.3390/jcm13092537.

Abstract

This study aimed to compare keratometry and anterior chamber depth (ACD) changes after XEN implantation in primary open-angle glaucoma (POAG) cases over a 3-month follow-up period. Twenty patients with POAG who underwent XEN63 implantation, either standalone or combined with cataract surgery, were included. Preoperative data, including best-corrected visual acuity (BCVA), refraction, gonioscopy, ophthalmoscopy, intraocular pressure (IOP) evaluation, and axial length, were collected. Corneal topography and ACD measurements were assessed preoperatively and at postoperative days 1, 7, 15, 30, 60, and 90. Each patient's eye that underwent XEN surgery was included in the study group, with the fellow eye serving as a control. In the study group, there was a significant decrease in IOP after XEN stent implantation at all investigated time intervals ( < 0.05). However, changes in mean ACD did not show statistically significant differences at any follow-up examination in both the study and control groups. Additionally, keratometry readings revealed no significant changes in total astigmatism or steep keratometry values in either group. XEN implantation in POAG cases resulted in a significant decrease in IOP over the 3-month follow-up period. However, there were no significant changes observed in mean ACD or keratometry readings, indicating stability in these parameters post-XEN implantation. These findings suggest that XEN implantation may be an effective option for IOP reduction without affecting corneal curvature or ACD in POAG patients.

摘要

本研究旨在比较原发性开角型青光眼(POAG)患者在植入XEN后的3个月随访期内角膜曲率和前房深度(ACD)的变化。纳入了20例接受XEN63植入术的POAG患者,这些患者单独接受植入术或联合白内障手术。收集术前数据,包括最佳矫正视力(BCVA)、验光、前房角镜检查、检眼镜检查、眼压(IOP)评估和眼轴长度。在术前以及术后第1天、第7天、第15天、第30天、第60天和第90天评估角膜地形图和ACD测量值。接受XEN手术的每只患眼纳入研究组,对侧眼作为对照。在研究组中,XEN支架植入后在所有研究的时间间隔内IOP均显著降低(<0.05)。然而,研究组和对照组在任何随访检查中平均ACD的变化均未显示出统计学上的显著差异。此外,角膜曲率测量结果显示两组的总散光或陡峭角膜曲率值均无显著变化。POAG患者植入XEN后在3个月随访期内IOP显著降低。然而,平均ACD或角膜曲率测量值未观察到显著变化,表明XEN植入后这些参数具有稳定性。这些发现表明,对于POAG患者,XEN植入可能是一种有效降低IOP的选择,且不影响角膜曲率或ACD。

相似文献

本文引用的文献

8
Glaucoma surgery and induced astigmatism: a systematic review.青光眼手术与诱导性散光:一项系统综述。
Eye Vis (Lond). 2017 Nov 17;4:27. doi: 10.1186/s40662-017-0090-x. eCollection 2017.