Menozzi Grazia Chiara, Depaoli Alessandro, Ramella Marco, Alessandri Giulia, Frizziero Leonardo, De Rosa Adriano, Soncini Francesco, Sassoli Valeria, Rocca Gino, Trisolino Giovanni
Unit of Pediatric Orthopedics and Traumatology, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy.
Rizzoli Sicilia Department, IRCCS Istituto Ortopedico Rizzoli, 90011 Bagheria, Italy.
Polymers (Basel). 2024 Apr 26;16(9):1216. doi: 10.3390/polym16091216.
(1) Background: Orthopedic surgery has been transformed by 3D-printed personalized instruments (3DP-PSIs), which enhance precision and reduce complications. Hospitals are adopting in-house 3D printing facilities, using cost-effective methods like Fused Deposition Modeling (FDM) with materials like Polylactic acid (PLA) to create 3DP-PSI. PLA's temperature limitations can be overcome by annealing High-Temperature PLA (ann-HTPLA), enabling steam sterilization without compromising properties. Our study examines the in vivo efficacy of ann-HTPLA 3DP-PSI in pediatric orthopedic surgery. (2) Methods: we investigated safety and efficacy using ann-HTPLA 3DP-PSI produced at an "in-office" 3D-printing Point-of-Care (3DP-PoC) aimed at correcting limb deformities in pediatric patients. Data on 3DP-PSI dimensions and printing parameters were collected, along with usability and complications. (3) Results: Eighty-three ann-HTPLA 3DP-PSIs were utilized in 33 patients (47 bone segments). The smallest guide used measured 3.8 cm, and the largest measured 58.8 cm. Seventy-nine PSIs (95.2%; 95% C.I.: 88.1-98.7%) demonstrated effective use without issues. Out of 47 procedures, 11 had complications, including 2 infections (4.3%; 95% CI: 0.5-14.5%). Intraoperative use of 3DP-PSIs did not significantly increase infection rates or other complications. (4) Conclusions: ann-HTPLA has proven satisfactory usability and safety as a suitable material for producing 3DP-PSI in an "in-office" 3DP-PoC.
(1) 背景:3D打印个性化器械(3DP - PSIs)已经改变了骨科手术,提高了手术精度并减少了并发症。医院正在采用内部3D打印设备,使用诸如熔融沉积建模(FDM)等经济高效的方法,以及聚乳酸(PLA)等材料来制造3DP - PSIs。通过对高温聚乳酸(ann - HTPLA)进行退火处理,可以克服PLA的温度限制,实现蒸汽灭菌且不影响其性能。我们的研究考察了ann - HTPLA 3DP - PSIs在小儿骨科手术中的体内疗效。(2) 方法:我们使用在“办公室内”即时3D打印点(3DP - PoC)生产的ann - HTPLA 3DP - PSIs来研究其安全性和疗效,旨在矫正小儿患者的肢体畸形。收集了3DP - PSIs尺寸和打印参数的数据,以及可用性和并发症数据。(3) 结果:33例患者(47个骨段)使用了83个ann - HTPLA 3DP - PSIs。使用的最小导向器尺寸为3.8厘米,最大为58.8厘米。79个PSIs(95.2%;95%置信区间:88.1 - 98.7%)使用效果良好,无问题。在47例手术中,11例出现并发症,包括2例感染(4.3%;95%置信区间:0.5 - 14.5%)。术中使用3DP - PSIs并未显著增加感染率或其他并发症。(4) 结论:ann - HTPLA作为在“办公室内”3DP - PoC生产3DP - PSIs的合适材料,已证明具有令人满意的可用性和安全性。