Reliability of a Trunk Flexion and Extensor Muscle Strength Test with Hand-Held and Isokinetic Dynamometers in Female Athletes.

作者信息

Juan-Recio Casto, Prat-Luri Amaya, Barbado David, Vera-Garcia Francisco J, Moreno-Pérez Víctor

机构信息

Sports Research Centre, Department of Sports Sciences, Miguel Hernández University of Elche, Alicante, Spain.

出版信息

J Hum Kinet. 2023 Nov 28;92:43-52. doi: 10.5114/jhk/172640. eCollection 2024 Apr.

Abstract

An accurate trunk muscle strength assessment seems very important to design and individualize training and rehabilitation programs in clinical and sport settings. Hand-held dynamometers (HHDs) are interesting alternatives to isokinetic dynamometers for assessing trunk isometric muscle strength because they are inexpensive instruments and easy to use. This cross-sectional observational study aimed to examine the reliability of two novel sitting tests for assessing trunk flexion and extension isometric strength using an HHD and their relationship with two other novel isometric tests that use an isokinetic dynamometer. Twenty-four female amateur athletes (age: 24.5 ± 2.64 years; body height: 164.45 ± 6.33 cm; body mass: 63.17 ± 10.35 kg) participated in this study. A test-retest design was carried out one-week apart to examine the reliability. The relationship and the degree of agreement between the HHD and the isokinetic dynamometer measurements were analysed using Pearson correlation and Bland-Altman analysis, respectively. In general, the reliability of all isometric strength tests was good, with ICCs ranging from 0.65 to 0.87 and typical error < 15%. Pearson correlations were moderate, with values of r = 0.47 (R = 0.22) and r = 0.42 (R = 0.18) for flexion and extension strength, respectively. Bland-Altman plots showed no agreement between HHDs and isokinetic measurements. All trunk isometric tests using both, an isokinetic dynamometer and HHDs, provide reliable measurements for assessing trunk flexion and extension strength. According to the comparative analysis, both measurement types are different and cannot be used interchangeably. Health and sport professionals should choose the test that best suits the biomechanical characteristics required for functional goals or success in a given sport.

摘要

在临床和运动环境中,准确评估躯干肌肉力量对于设计个性化的训练和康复计划似乎非常重要。手持测力计(HHD)是用于评估躯干等长肌肉力量的等速测力计的有趣替代方案,因为它们价格低廉且易于使用。这项横断面观察性研究旨在检验两种新型坐姿测试使用HHD评估躯干屈伸等长力量的可靠性,以及它们与另外两种使用等速测力计的新型等长测试之间的关系。24名女性业余运动员(年龄:24.5±2.64岁;身高:164.45±6.33厘米;体重:63.17±10.35千克)参与了本研究。采用重测设计,间隔一周进行测试以检验可靠性。分别使用Pearson相关性分析和Bland-Altman分析来分析HHD和等速测力计测量值之间的关系和一致性程度。总体而言,所有等长力量测试的可靠性良好,组内相关系数(ICC)范围为0.65至0.87,典型误差<15%。Pearson相关性为中等,屈伸力量的相关系数分别为r = 0.47(R = 0.22)和r = 0.42(R = 0.18)。Bland-Altman图显示HHD和等速测量之间不一致。使用等速测力计和HHD的所有躯干等长测试都能为评估躯干屈伸力量提供可靠的测量。根据比较分析,两种测量类型不同,不能互换使用。健康和运动专业人员应选择最适合特定运动功能目标或成功所需生物力学特征的测试。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8f6a/11079922/9329fa7aca7f/JHK-92-172640-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验