To report gross anatomical gastrointestinal measurements and compare enterotomy leak pressures between fresh and cooled feline cadavers.
Ex vivo, randomized study.
Fresh feline cadavers (n = 20).
Jejunal segments (8 cm) were harvested on the same day as euthanasia. From each cadaver, one segment was randomly assigned to control (C), fresh enterotomy (FE), and cooled enterotomy (CE) groups. Enterotomy construction and leak testing were performed within 12 h of euthanasia for the C and FE groups and after 17-29 h of cooling for the CE group. Initial leak pressure (ILP) and maximum intraluminal pressure (MIP) were compared. Gastrointestinal wall thickness and intraluminal diameter were measured on harvested applicable gastrointestinal divisions at up to three time points: day 1 fresh, day 2 cooled, and day 3 cooled.
The mean (± SD) ILPs for the C, FE, and CE constructs were 600 (± 0.0), 200.3 (± 114.7), and 131.3 (± 92.6) mmHg, respectively. The C ILP was higher (p < .001) than the FE and CE ILP. The ILP (p = .11) and the MIP (p = .21) did not differ between the FE and CE constructs. Wall thickness (measured in mm) did not differ between duodenum day 1 fresh and day 2 cooled groups (p = .18) or between any jejunum day groups (p = .86). The intraluminal diameters (mean ± SD) for the duodenum, jejunum, and ileum were 5.7 (± 0.7), 5.8 (± 0.8), and 7.2 (± 2.2) mm, respectively.
No difference was appreciated between FE and CE ILP and MIP. Wall thickness measurements did not differ between days for duodenum or jejunum.
Cadaveric feline intestine cooled for up to 29 h may be used for determining intestinal leak pressures.
报告大体解剖胃肠道测量值,并比较新鲜和冷藏猫尸体的肠切开漏压。
离体、随机研究。
新鲜猫尸体(n=20)。
在安乐死后的同一天收获空肠段(8cm)。每个尸体的一段随机分为对照(C)、新鲜肠切开(FE)和冷藏肠切开(CE)组。C 和 FE 组在安乐死后 12 小时内进行肠切开构建和漏测,CE 组在冷却 17-29 小时后进行。比较初始漏压(ILP)和最大腔内压力(MIP)。在多达三个时间点测量收获的适用胃肠道部位的胃肠道壁厚度和腔内直径:第 1 天新鲜、第 2 天冷藏和第 3 天冷藏。
C、FE 和 CE 结构的平均(±SD)ILP 分别为 600(±0.0)、200.3(±114.7)和 131.3(±92.6)mmHg。C ILP 高于 FE 和 CE ILP(p<0.001)。FE 和 CE 结构的 ILP(p=0.11)和 MIP(p=0.21)无差异。十二指肠第 1 天新鲜和第 2 天冷藏组(p=0.18)或任何空肠组(p=0.86)之间的壁厚度无差异。十二指肠、空肠和回肠的腔内直径(平均值±SD)分别为 5.7(±0.7)、5.8(±0.8)和 7.2(±2.2)mm。
FE 和 CE 的 ILP 和 MIP 无差异。十二指肠或空肠的日壁厚度测量无差异。
冷藏长达 29 小时的猫尸体肠段可用于确定肠漏压。