Suppr超能文献

髋臼顶角度对全髋关节置换术中髋臼杯旋转中心再现及放置精度的影响。

Impact of acetabular roof's angle on precision of cup center of rotation reproduction and placement in total hip arthroplasty.

作者信息

Maciąg Bartosz, Jegierski Dawid, Wilk Bartłomiej, Budzińska Martyna, Maciąg Grzegorz, Kupczak Anna, Żarnovsky Krystian, Łapiński Marcin, Kordyaczny Tomasz, Stolarczyk Artur

机构信息

Department of Orthopedics and Rehabilitation, Miedzyleski Specialist Hospital, Medical University of Warsaw, Poland.

出版信息

Reumatologia. 2024;62(2):128-133. doi: 10.5114/reum/186724. Epub 2024 Apr 18.

Abstract

INTRODUCTION

Total hip arthroplasty (THA) is nowadays considered as the most effective treatment option for end-stage hip osteoarthritis (OA) and one of the most successful orthopedic procedures. Precise reproduction of the center of rotation (COR) is among the most important aspects of recreating native hip biomechanics after THA as it is strictly related to muscle tension and force distribution within the hip joint. Both vertical and horizontal shift in cup positioning and COR restoration are commonly observed radiological signs corresponding with lesser functional outcome. The aim of this study was to assess whether the superior border of the native acetabulum morphology has an impact on cup positioning and COR restoration in patients undergoing THA as treatment of primary OA of the hip.

MATERIAL AND METHODS

A cohort of 150 consecutive patients with diagnosis of end-stage primary hip OA who underwent THA via an anterolateral approach with the same implant in 2021 was analyzed retrospectively. Standard standing pelvic X-rays were performed pre- and postoperatively and appropriate measurements were taken. Several radiological parameters on obtained X-rays were assessed. Statistical analysis of all the measurements was performed.

RESULTS

There was a statistically significant positive weak correlation between cup offset and acetabular roof angle ( = 0.25, = 0.002). There were statistically insignificant positive correlations between acetabular roof angle and COR restoration ( = 0.14, = 0.097), acetabular roof angle and total offset ( = 0.087, = 0.29) and a negative correlation between acetabular roof angle and femoral offset ( = 0.071, = 0.39).

CONCLUSIONS

The present study revealed that preoperative acetabular roof angle influences the positioning of the prosthetic cup in the transverse axis. There also seems to be a correlation between the acetabular roof angle and COR restoration, but its significance needs further evaluation. Surgeons could use this knowledge to preoperatively assess the risk of cup malposition and adjust their technique during the THA procedure with probable improvement of hip function.

摘要

引言

全髋关节置换术(THA)如今被认为是终末期髋关节骨关节炎(OA)最有效的治疗选择,也是最成功的骨科手术之一。旋转中心(COR)的精确重建是THA术后重建天然髋关节生物力学的最重要方面之一,因为它与髋关节内的肌肉张力和力分布密切相关。髋臼杯位置的垂直和水平偏移以及COR重建是常见的放射学征象,与较差的功能结果相关。本研究的目的是评估天然髋臼形态的上缘对接受THA治疗原发性髋关节OA患者的髋臼杯位置和COR重建是否有影响。

材料与方法

回顾性分析2021年连续150例诊断为终末期原发性髋关节OA并通过前外侧入路使用相同植入物进行THA的患者队列。术前和术后均进行标准站立位骨盆X线检查并进行适当测量。对获得的X线片上的几个放射学参数进行评估。对所有测量值进行统计分析。

结果

髋臼杯偏移与髋臼顶角度之间存在统计学上显著的正弱相关性(r = 0.25,p = 0.002)。髋臼顶角度与COR重建(r = 0.14,p = 0.097)、髋臼顶角度与总偏移(r = 0.087,p = 0.29)之间存在统计学上不显著的正相关性,而髋臼顶角度与股骨偏移之间存在负相关性(r = 0.071,p = 0.39)。

结论

本研究表明术前髋臼顶角度会影响假体髋臼杯在横轴上的位置。髋臼顶角度与COR重建之间似乎也存在相关性,但其意义需要进一步评估。外科医生可以利用这一知识在术前评估髋臼杯位置不当的风险,并在THA手术过程中调整技术,可能改善髋关节功能。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ead9/11114134/da2afa73226c/RU-62-186724-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验