Suppr超能文献

氧化再生纤维素粉末在全膝关节置换术中的过敏反应

Hypersensitive Reaction of Oxidized Regenerated Cellulose Powder in Total Knee Arthroplasty.

作者信息

Mikashima Yoshinori, Imamura Hitoshi, Shirakawa Yoshiko, Takagi Hiroshi, Okazaki Ken

机构信息

Oume Knee Surgery Center, Takagi Hospital, Tokyo, JPN.

Department of Orthopaedics, Tokyo Women's Medical University Adachi Medical Center, Tokyo, JPN.

出版信息

Cureus. 2024 Apr 26;16(4):e59097. doi: 10.7759/cureus.59097. eCollection 2024 Apr.

Abstract

The powdered form of oxidized regenerated cellulose (ORC powder) is a widely used biodegradable hemostatic material in the field of surgery. There are several reports of its effectiveness and safety; however, excessive foreign body reactions remain a concern for surgeons in total knee arthroplasty (TKA). A 70-year-old woman who underwent unilateral TKA using ORC powder to control perioperative blood loss exhibited a skin rash around her operated knee at six days postoperatively. These reactions were potentially hypersensitive to ORC powder. After receiving antiallergic medication for 18 days, the skin rash disappeared. Although there are several reports on the safety of ORC powder, inadequate intraoperative lavage of the product may induce hypersensitive reactions such as skin rash.

摘要

氧化再生纤维素粉末(ORC粉末)是外科领域广泛使用的可生物降解止血材料。有多项关于其有效性和安全性的报道;然而,在全膝关节置换术(TKA)中,过度的异物反应仍是外科医生关注的问题。一名70岁女性在接受单侧TKA手术时使用ORC粉末控制围手术期失血,术后第6天手术膝关节周围出现皮疹。这些反应可能是对ORC粉末过敏。接受抗过敏药物治疗18天后,皮疹消失。虽然有多项关于ORC粉末安全性的报道,但术中对该产品冲洗不充分可能会引发皮疹等过敏反应。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/c408/11128366/c1a2dd5cda32/cureus-0016-00000059097-i01.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验