Mikashima Yoshinori, Imamura Hitoshi, Shirakawa Yoshiko, Takagi Hiroshi, Okazaki Ken
Oume Knee Surgery Center, Takagi Hospital, Tokyo, JPN.
Department of Orthopaedics, Tokyo Women's Medical University Adachi Medical Center, Tokyo, JPN.
Cureus. 2024 Apr 26;16(4):e59097. doi: 10.7759/cureus.59097. eCollection 2024 Apr.
The powdered form of oxidized regenerated cellulose (ORC powder) is a widely used biodegradable hemostatic material in the field of surgery. There are several reports of its effectiveness and safety; however, excessive foreign body reactions remain a concern for surgeons in total knee arthroplasty (TKA). A 70-year-old woman who underwent unilateral TKA using ORC powder to control perioperative blood loss exhibited a skin rash around her operated knee at six days postoperatively. These reactions were potentially hypersensitive to ORC powder. After receiving antiallergic medication for 18 days, the skin rash disappeared. Although there are several reports on the safety of ORC powder, inadequate intraoperative lavage of the product may induce hypersensitive reactions such as skin rash.