Suppr超能文献

男性中长跑运动员多级递增式跑步机测试中跑步经济性、代谢及心肺参数的重测信度

Test-Retest Reliability of Running Economy and Metabolic and Cardiorespiratory Parameters During a Multistage Incremental Treadmill Test in Male Middle- and Long-Distance Runners.

作者信息

Brady Aidan J, Roantree Mark, Egan Brendan

机构信息

School of Health and Human Performance, Dublin City University, Glasnevin, Dublin, Ireland.

Insight Centre for Data Analytics, Dublin City University, Glasnevin, Dublin, Ireland.

出版信息

Int J Sport Nutr Exerc Metab. 2024 May 31;34(5):307-314. doi: 10.1123/ijsnem.2023-0272. Print 2024 Sep 1.

Abstract

This study investigated the test-retest reliability of running economy (RE) and metabolic and cardiorespiratory parameters related to endurance running performance using a multistage incremental treadmill test. On two occasions separated by 21-28 days, 12 male middle- and long-distance runners ran at 10, 11, 12, 13, and 14 km/hr for 8 min each stage, immediately followed by a ramp test to volitional exhaustion. Carbohydrate (10% maltodextrin solution) was consumed before and during the test to provide ∼1 g/min of exercise. RE, minute ventilation (V˙E), oxygen consumption (V˙O2), carbon dioxide production (V˙CO2), respiratory exchange ratio (RER), heart rate (HR), ratings of perceived exertion (RPE), and blood glucose and lactate concentrations were recorded for each stage and at volitional exhaustion. Time-to-exhaustion (TTE) and peak oxygen consumption (V˙O2peak) during the ramp test were also recorded. Absolute reliability, calculated as the coefficient of variation (CV) between repeated measures, ranged from 2.3% to 3.1% for RE, whereas relative reliability, calculated as the intraclass correlation coefficient (ICC), ranged from .42 to .79. V˙E, V˙O2, V˙O2peak, V˙CO2, RER, and HR had a CV of 1.1%-4.3% across all stages. TTE and RPE had a CV of 7.2% and 2.3%-10.8%, respectively, while glucose and lactate had a CV of 4.0%-17.8%. All other parameters, except for blood glucose, were demonstrated to have good-to-excellent relative reliability assessed by ICC. Measures of RE, V˙O2peak, and TTE were reliable during this two-phase multistage incremental treadmill test in a cohort of trained and highly trained male middle- and long-distance runners.

摘要

本研究使用多级递增式跑步机测试,调查了跑步经济性(RE)以及与耐力跑表现相关的代谢和心肺参数的重测信度。在间隔21 - 28天的两个时间段,12名男性中长跑运动员在每个阶段以10、11、12、13和14公里/小时的速度跑8分钟,随后立即进行递增测试直至自愿疲劳。在测试前和测试期间摄入碳水化合物(10%的麦芽糊精溶液),以提供约1克/分钟的运动供能。记录每个阶段以及自愿疲劳时的RE、分钟通气量(V˙E)、耗氧量(V˙O2)、二氧化碳产生量(V˙CO2)、呼吸交换率(RER)、心率(HR)、自觉用力程度评分(RPE)以及血糖和乳酸浓度。还记录递增测试期间的疲劳时间(TTE)和峰值耗氧量(V˙O2peak)。重复测量之间的变异系数(CV)计算得出的绝对信度,RE为2.3%至3.1%,而组内相关系数(ICC)计算得出的相对信度为0.42至0.79。所有阶段中,V˙E、V˙O2、V˙O2peak、V˙CO2、RER和HR的CV为1.1% - 4.3%。TTE和RPE的CV分别为7.2%和2.3% - 10.8%,而葡萄糖和乳酸的CV为4.0% - 17.8%。除血糖外,所有其他参数经ICC评估均具有良好至优秀的相对信度。在一组训练有素和训练有素的男性中长跑运动员中,在这个两阶段的多级递增式跑步机测试期间,RE、V˙O2peak和TTE的测量是可靠的。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验