BACKGROUND

Self-Care of Chronic Illness Inventory version 4c is a non-disease-specific self-care measure used in individuals with multiple chronic conditions. This instrument may be applied to patients with specific diseases such as stroke.

OBJECTIVE

The aim of this study was to evaluate the psychometric properties of the Thai version of the Self-Care of Chronic Illness Inventory version 4c in patients with stroke.

METHODS

This multicenter, cross-sectional study adhered to the COSMIN (Consensus-based Standards for the Selection of Health Measurement Instruments) guidelines and enrolled patients with stroke from 16 primary care centers in southern Thailand. Structural validity was assessed using confirmatory factor analysis, internal consistency reliability using Cronbach α coefficient and global reliability index, and test-retest reliability using intraclass correlation coefficients.

RESULTS

The final analysis included a total of 350 participants. Confirmatory factor analysis supported the 2-factor Self-Care Maintenance scale structure, although the item allocation to the dimensions differed from that of the original model. The Self-Care Monitoring scale demonstrated a 1-factor structure with permitted residual covariance. The Self-Care Management scale maintained a 2-factor structure, similar to that of the original model. Simultaneous confirmatory factor analysis of the combined items supported the general model with the 3 scales. The Self-Care Maintenance scale exhibited marginally adequate α (0.68) and ω (0.66) coefficients, and an adequate composite reliability index (0.79). The other 2 scales demonstrated adequate α (range, 0.79-0.86), ω (range, 0.75-0.86), and composite reliability (range, 0.83-0.86) indices. Intraclass correlation coefficients showed adequate test-retest reliability for all scales (range, 0.76-0.90).

CONCLUSIONS

The generic self-care measure, Self-Care of Chronic Illness Inventory version 4c, demonstrated strong psychometric properties in patients with stroke. This instrument may be a valuable tool for assessing stroke self-care in Thailand.

摘要

背景

慢性病自我护理量表第4c版是一种用于患有多种慢性病个体的非疾病特异性自我护理测量工具。该工具可应用于中风等特定疾病的患者。

目的

本研究旨在评估中风患者中泰语版慢性病自我护理量表第4c版的心理测量特性。

方法

本多中心横断面研究遵循COSMIN(健康测量工具选择的基于共识的标准)指南,纳入了泰国南部16个初级保健中心的中风患者。使用验证性因子分析评估结构效度,使用Cronbach α系数和总体可靠性指数评估内部一致性信度,使用组内相关系数评估重测信度。

结果

最终分析共纳入350名参与者。验证性因子分析支持两因子的自我护理维持量表结构,尽管各维度的项目分配与原始模型不同。自我护理监测量表显示为具有允许残差协方差的单因子结构。自我护理管理量表保持两因子结构,与原始模型相似。对合并项目进行的同时验证性因子分析支持包含这三个量表的总体模型。自我护理维持量表的α系数(0.68)和ω系数(0.66)略为适当,综合可靠性指数适当(0.79)。其他两个量表显示α系数(范围为0.79 - 0.86)、ω系数(范围为0.75 - 0.86)和综合可靠性(范围为0.83 - 0.86)指数适当。组内相关系数显示所有量表的重测信度适当(范围为0.76 - 0.90)。