Am J Vet Res. 2024 Jun 26;85(8). doi: 10.2460/ajvr.24.03.0065. Print 2024 Aug 1.
To demonstrate hypercoagulability with a benchtop viscoelastic monitor in cats with congestive heart failure (CHF) and/or aortic thromboembolism (ATE) compared to controls.
97 cats were enrolled throughout this prospective observational cohort study from September 2022 through October 2023. Cats were grouped by diagnosis of CHF, ATE, ATE plus CHF, or controls. Enrollment required diagnosis of heart disease and no previous antithrombotic therapy. The results of viscoelastic testing with the benchtop viscoelastic coagulation monitor (VCM Vet [VCM]; Entegrion) were compared between groups using factorial analysis of variance.
Cats with heart disease had significantly higher clot times when compared to controls (control: mean, 285.3 [SD, 172.6]; CHF: mean, 391.7 [SD, 106.8]; ATE: mean, 415.9 [SD, 109.2]; and ATE plus CHF: mean, 368.6 [SD, 232.6]). Heart disease cats were noted to have significantly lower 45-minute lysis index values (control: median, 100 [range, 93 to 100]; CHF: median, 99 [range, 89 to 100]; ATE: median, 98 [range, 88 to 100]; and ATE plus CHF: range, 98 [91 to 100]). Age was a covariate to this variable, and when applied to analysis, statistical significance was lost. No significant difference in any other variables were noted.
The hypercoagulability of ATE and CHF cats was not detected by the VCM. Further research with other coagulation monitors is required in this population.
与对照组相比,使用台式黏度计监测仪检测充血性心力衰竭(CHF)和/或主动脉血栓栓塞(ATE)猫的高凝状态。
本前瞻性观察队列研究于 2022 年 9 月至 2023 年 10 月期间共纳入 97 只猫。根据诊断结果将猫分为 CHF 组、ATE 组、ATE 合并 CHF 组或对照组。入组标准为诊断为心脏病且无既往抗血栓治疗。使用台式黏度计监测仪(VCM Vet [VCM];Entegrion)进行黏度检测,使用析因方差分析比较各组间的检测结果。
与对照组相比,患有心脏病的猫的凝块时间显著增加(对照组:平均值 285.3 [标准差 172.6];CHF 组:平均值 391.7 [标准差 106.8];ATE 组:平均值 415.9 [标准差 109.2];ATE 合并 CHF 组:平均值 368.6 [标准差 232.6])。患有心脏病的猫的 45 分钟溶解指数值显著降低(对照组:中位数 100 [范围 93 至 100];CHF 组:中位数 99 [范围 89 至 100];ATE 组:中位数 98 [范围 88 至 100];ATE 合并 CHF 组:范围 98 [91 至 100])。年龄是该变量的一个协变量,当应用于分析时,统计学意义丧失。未观察到其他变量有显著差异。
ATE 和 CHF 猫的高凝状态未被 VCM 检测到。在该人群中需要使用其他凝血监测仪进行进一步研究。