Suppr超能文献

体外合成人免疫球蛋白:两种分泌型免疫球蛋白检测方法的比较

Synthesis of human immunoglobulins in vitro: comparison of two assays of secreted immunoglobulin.

作者信息

Jokinen I, Poikonen K, Arvilommi H

出版信息

J Immunoassay. 1985;6(1-2):1-9. doi: 10.1080/01971528508063017.

Abstract

One consequence of B-lymphocyte activation is immunoglobulin production, which can be quantitated by various techniques. We have compared assay of plaque forming cell (PFC) and determination of immunoglobulins by ELISA in culture supernatants of human lymphocytes stimulated with pokeweed mitogen and with Staphylococcus aureus. These assays correlated well (r greater than 0.77) in all major immunoglobulin classes studied. The close correlation suggests that determination of secreted immunoglobulins by ELISA may be substituted for the PFC assay.

摘要

B淋巴细胞激活的一个结果是免疫球蛋白产生,这可以通过多种技术进行定量。我们比较了用美洲商陆丝裂原和金黄色葡萄球菌刺激的人淋巴细胞培养上清液中噬斑形成细胞(PFC)测定法和ELISA法测定免疫球蛋白。在所有研究的主要免疫球蛋白类别中,这些测定法相关性良好(r大于0.77)。这种密切相关性表明,ELISA法测定分泌型免疫球蛋白可以替代PFC测定法。