AURA Veterinary, Guildford, UK.
Fitzpatrick Referrals Oncology and Soft Tissue, Guildford, UK.
J Vet Emerg Crit Care (San Antonio). 2024 Jul-Aug;34(4):376-386. doi: 10.1111/vec.13403. Epub 2024 Jul 7.
To determine the number of homologous blood transfusions received by canine surgical patients after introducing a cell salvage device (CSD), trends in surgeries requiring blood transfusion, and the incidence of transfusion reactions.
Retrospective study.
Single referral hospital.
All dogs having surgery at a single center (November 2015 to February 2021).
Medical records of dogs having surgical treatment, including those that received either an autologous or homologous blood transfusion, were reviewed. The surgical patients were the baseline population, and the 2 transfusion groups were compared within this population to analyze the trends.
A total of 37 and 86 dogs received autologous and homologous blood transfusions, respectively. There was an upward trend in the number of total monthly blood transfusions. No significant increase in the monthly number of homologous transfusions was observed before or after acquisition of the CSD. There was also an upward trend in total monthly surgeries, including those with higher risks of hemorrhage. Dogs receiving homologous blood transfusions had a higher incidence of clinical signs consistent with transfusion reactions (6.98%).
An upward trend in autologous blood transfusions was seen with the introduction of a CSD. Hospitals with large surgical caseloads at high risk of hemorrhage may see a decreased need for outsourced blood products with the use of the CSD. The device can lead to a more responsible use of an increasingly scarce resource and decrease the risk of a blood transfusion reaction in dogs.
确定引入细胞保存装置(CSD)后接受同种异体输血的犬外科患者数量、需要输血的手术趋势以及输血反应的发生率。
回顾性研究。
单转诊医院。
在单一中心接受手术的所有犬(2015 年 11 月至 2021 年 2 月)。
回顾接受自体或同种异体输血的接受外科治疗的犬的病历。手术患者为基线人群,并在该人群内比较这 2 个输血组以分析趋势。
共 37 只和 86 只犬分别接受了自体和同种异体输血。总每月输血数量呈上升趋势。在获得 CSD 之前或之后,同种异体输血的每月数量没有明显增加。总每月手术数量也呈上升趋势,包括出血风险较高的手术。接受同种异体输血的犬出现与输血反应一致的临床症状的发生率更高(6.98%)。
随着 CSD 的引入,自体输血呈上升趋势。具有大量高出血风险手术的医院可能会随着 CSD 的使用而减少对外购血液制品的需求。该设备可以更负责任地使用日益稀缺的资源,并降低犬输血反应的风险。