Wellcome Trust/CRUK Gurdon Institute and Department of Physiology, Development and Neuroscience, University of Cambridge, Cambridge, UK.
Methods Mol Biol. 2024;2805:161-169. doi: 10.1007/978-1-0716-3854-5_11.
Pressure exerted by fluid contained within a lumen plays a crucial role in the growth, morphogenesis, and patterning of epithelial organs. Accurate modulation of lumen pressure in the developing embryo requires sensitive and robust methods that can detect and vary pressure in the range of tens to hundreds of Pascals (Pa). Here we describe a simple, cost-effective protocol for setting up a pressure modulation apparatus combining a high-sensitivity pressure sensor and a water column whose height can be finely tuned. We demonstrate lumen pressure control using the developing brain of early chicken embryos.
管腔内流体所产生的压力在上皮组织器官的生长、形态发生和模式形成过程中起着至关重要的作用。要在发育中的胚胎中准确地调节管腔压力,就需要使用能够检测并在数十到数百帕斯卡(Pa)范围内改变压力的灵敏且稳健的方法。本文中,我们描述了一种简单、经济高效的压力调节装置的搭建方案,该方案结合了高灵敏度压力传感器和可以精细调节高度的水柱。我们使用早期鸡胚的发育大脑来演示管腔压力控制。