Suppr超能文献

基于 FAERS 数据库的放射诊断用碘造影剂致超敏反应:一项比例失调分析。

Hypersensitivity Reactions Induced by Iodinated Contrast Media in Radiological Diagnosis: A Disproportionality Analysis Based on the FAERS Database.

机构信息

Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong 637000, China.

出版信息

Curr Med Imaging. 2024;20:e15734056306358. doi: 10.2174/0115734056306358240607115422.

Abstract

PURPOSE

This study aimed to evaluate the Pharmacovigilance (PV) and severity of hypersensitivity reactions induced by non-ionic Iodinated Contrast Media (ICM) in the radiology diagnosis reported to the United States Food and Drug Administration Adverse Event Reporting System (FAERS).

METHODS

We retrospectively reviewed the reports of ICM-induced hypersensitivity reactions submitted to the FAERS database between January 2015 and January 2023 and conducted a disproportionality analysis. The seven most common non-ionic ICM, including iohexol, iopamidol, ioversol, iopromide, iomeprol, iobitridol, and iodixanol, were chiefly analyzed. Our primary endpoint was the PV of non-ionic ICM-induced total hypersensitivity events. STATA 17.0 MP was used for statistical analysis.

RESULTS

In total, 35357 reports of adverse reaction events in radiology diagnosis were retrieved from the FAERS database. Among them, 6181 reports were on hypersensitivity reaction events (mean age: 57.1 ± 17.8 years). The hypersensitivity reaction-related PV signal was detected for iohexol, ioversol, iopromide, iomeprol, iobitridol, and iodixanol, but not for iopamidol. The proportion of iomeprol-induced hypersensitivity reactions and the probability of ioversol-induced severe hypersensitivity reactions have been found to be significantly increased.

CONCLUSION

The probability and severity of hypersensitivity reaction events in non-ionic ICM are different. Iohexol, ioversol, iopromide, iomeprol, iobitridol, and iodixanol have higher risks compared to iopamidol. In addition, the constituent ratio of hypersensitivity reactions induced by iomeprol is significantly increased, and the associated probability induced by ioversol is significantly increased.

摘要

目的

本研究旨在评估美国食品和药物管理局不良事件报告系统(FAERS)中报告的放射诊断用非离子型碘造影剂(ICM)引起的药物警戒(PV)和过敏反应严重程度。

方法

我们回顾性分析了 2015 年 1 月至 2023 年 1 月期间向 FAERS 数据库报告的 ICM 诱导的过敏反应报告,并进行了比例失衡分析。主要分析了七种最常见的非离子型 ICM,包括碘海醇、碘帕醇、碘佛醇、碘普罗胺、碘美普尔、碘比醇和碘克沙醇。我们的主要终点是非离子型 ICM 引起的总过敏反应事件的 PV。使用 STATA 17.0 MP 进行统计分析。

结果

从 FAERS 数据库中总共检索到 35357 份放射诊断不良事件报告。其中,6181 份报告为过敏反应事件(平均年龄:57.1 ± 17.8 岁)。检测到碘海醇、碘佛醇、碘普罗胺、碘美普尔、碘比醇和碘克沙醇的过敏反应相关 PV 信号,但未检测到碘帕醇的信号。碘美普尔诱导的过敏反应比例和碘佛醇诱导的严重过敏反应概率显著增加。

结论

非离子型 ICM 引起的过敏反应事件的概率和严重程度不同。与碘帕醇相比,碘海醇、碘佛醇、碘普罗胺、碘美普尔、碘比醇和碘克沙醇的风险更高。此外,碘美普尔诱导的过敏反应组成比例显著增加,碘佛醇诱导的过敏反应概率显著增加。